Manual e-MatriX 800
--------------------------------------------------------------------------------------------------------------------------------------
14 < < < <
12 Trouble shooting
The flame effect will not start.
Mains plug is not plugged in.
Low water level.
The transducers) are not connected
properly.
Check plug is connected to wall
socket correctly.
See Chapter 8.3.
Check that the connector(s) is
inserted correctly see fig. 7.0.
e-MatriX will not start or stopped
working and the LED’s continuously
to blink twice.
Low water level.
The absorption valve is activated
See Chapter 8.3.
Switch the mains switch of the
Control box to the OFF position.
Check all connections on water
leakage.
Check that the ball valves are open.
See Chapter 10.3.
e-MatriX will not operate, the LED’s
continuously to blink once every
eight seconds.
Check the electromechanical valve
in the Control box.
e-MatriX will not operate, the LED’s
continuously to blink four times.
Water filling time is too long.
Switch the mains switch of the
Control box to the OFF position and
heck all connections on water
leakage.
Close the ball valves and check the
mesh filter, by unscrewing the base
of it to see that it is not clogged with
dirt and debris.
The flame effect is too low on the
highest setting.
The transducers and/or air filter are
dirty.
The flame effect is too high and
there is too much smoke.
The extract fan doesn’t work
anymore.
Check if the fan, mounted at the top
inside the fire, is running.
Low batteries.
Remote isn’t paired to receiver.
Distance to fire too big
Place new batteries.
See Chapter 8.2.1.
See Chapter 9 (remote control).