EasyManua.ls Logo

Fagor 8065 - Page 23

Fagor 8065
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error solving manual.
CNC 8060
CNC 8065
·23·
(REF: 1709)
1060 'N label value out of range'
DETECTION During execution.
CAUSE Invalid block number "N".
SOLUTION The block number must be a positive value lower than 2147483646.
1061 'Nonexistent G function'
DETECTION During execution.
CAUSE The programmed G function does not exist.
SOLUTION Check the program.
1062 'Incompatible G functions'
DETECTION During execution.
CAUSE Two G functions incompatible with each other have been programmed in the block.
SOLUTION Program the functions in different blocks.
1063 'Incompatible G functions (G108/G109/G193)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1064 'Incompatible G functions (G196/G197)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1065 'Incompatible G functions (G17/G18/G19/G20)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1066 'Incompatible G functions (G136/G137)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1067 'Incompatible G functions (G40/G41/G42)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1068 'Incompatible G functions (G151/G152)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1069 'Incompatible G functions (G54-G59/G159)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.
1070 'Incompatible G functions (G5/G7/G50/G60/G61)'
DETECTION During execution.
CAUSE Two or more G functions incompatible with each other have been programmed in the
block.
SOLUTION Program the functions in different blocks.

Related product manuals