1094 'F feedrate programmed twice'
DETECTION During execution.
CAUSE More than one F function have been programmed in the same block.
SOLUTION Each block can only contain one F function. Program both functions in different
blocks.
1095 'Feedrate F cannot be negative or zero'
DETECTION During execution.
CAUSE The feedrate (F) must be positive and other than zero.
SOLUTION Check the program.
1096 'The feedrate cannot be programmed with E'
DETECTION During execution.
CAUSE The feedrate has been programmed with the E function.
SOLUTION Program the feedrate with the F function.
1097 'Unknown spindle name'
DETECTION During execution.
CAUSE The spindle name is not valid, the spindle does not exist in the system or the spindle
does not belong to the channel.
SOLUTION The valid names for the spindle are S, S1, ..., S9. The spindle programmed to in the
block must exist in the system configuration and depending on which instruction it
is, also in the channel configuration. A channel can only control its spindles.
1098 'S speed programmed twice'
DETECTION During execution.
CAUSE There are two or more S functions programmed for the same spindle in the same
block.
SOLUTION There can only be one speed for each spindle in the same block.
1100 'Parameter index out of range'
DETECTION During execution.
CAUSE The arithmetic parameter does not exist; it is not within the range admitted by the
machine parameters.
SOLUTION Check the program. Check the valid arithmetic parameter range in the machine
parameters.
1101 '#SET IPOPOS instruction programmed wrong'
DETECTION During execution.
CAUSE The syntax of the instruction is wrong or there is more data in the block.
SOLUTION Check the program. The instructions must be programmed alone in the block, only
the block label may be added.
1102 'The index for R cannot be other than 1'
DETECTION During execution.
CAUSE The radius can only be programmed with R or R1.
SOLUTION Check the program.
1103 'Nonexistent O function'
DETECTION During execution.
CAUSE The O function does not exist.
SOLUTION Check the program.
1104 'The "%" character is not allowed inside the main program'
DETECTION During execution.
CAUSE The "%" character can only be used as first character in the definition of the name
of the main program or of a local subroutine.
SOLUTION Remove this character from the program.
Machine parameters. Valid range.
MINLOCP - MAXLOCP Local arithmetic parameters.
MINGLBP - MAXGLBP Global arithmetic parameters.
MINCOMP - MAXCOMP Common arithmetic parameters.