The procedure for converting to a different gas for each model of gas oven is described below. This conversion
should only be carried out by an authorised technical service. To ensure that the conditions of the appliance correspond to
those defined at the factory, check that the CO values are less than 1000 ppm and the Lambda value is between 1.2-1.4
(VERY VERY IMPORTANT)
ACG-AG-APG 061 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed
Max. Speed Min. Speed Ø Injector Reference
LPG (G30-G31) 3500 5700 3600 Ø 4.4 12039657
NG (G20) 4000 6500 4200 Ø 6 12039566
QUEMADOR VAPOR/ Steam burner
Ignition Speed
Max. Speed Ø Injector Reference
LPG (G30-G31) 4000 4300 Ø 3.5 12045658
NG (G20) 4000 5000 Ø 4.55 12039565
ACG-AG-APG 101 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed Max. Speed Min. Speed Ø Injector Reference
LPG (G30-G31) 5000 6000 3600 Ø5 12039570
NG (G20) 5000 7500 4000 Ø7 12039569
QUEMADOR VAPOR/ Steam burner
Ignition Speed Max. Speed Ø Injector Reference
LPG (G30-G31) 5000 5700 Ø 3.5 12045658
NG (G20) 5000 6400 Ø 4.55 12039565
ACG-AG-APG 102 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed Max. Speed Min. Speed Ø Injector Reference
LPG (G30-G31) 5000 6000 3300 Ø 5.4 12045672
NG (G20) 5000 7500 4000 Ø 8 12045673
QUEMADOR VAPOR/ Steam burner
Ignition Speed Max. Speed Ø Injector Reference
LPG (G30-G31) 5500 5800 Ø 5.4 12045672
NG (G20) 5500 6600 Sin Inyector