7.
7.7.
7.-
--
-
IGNITION CONTROL SIT 579 DBC Ref. SAP: 12039440
IGNITION CONTROL SIT 579 DBC Ref. SAP: 12039440IGNITION CONTROL SIT 579 DBC Ref. SAP: 12039440
IGNITION CONTROL SIT 579 DBC Ref. SAP: 12039440
Principal characteristics
Principal characteristicsPrincipal characteristics
Principal characteristics: This component is used to start and control the burner.
Compact design
Assembled directly onto the gas valve
Ignition spark plug signal
Flame ionisation detector
Repetition of cycle when flame is lost during operation
Reset
Power supply 230 V AC
Protection IP 40
Minimum flame current 0.9 microA
Recommended flame current > 3 x minimum current
ELECTRICAL DIAGRAM
ELECTRICAL DIAGRAMELECTRICAL DIAGRAM
ELECTRICAL DIAGRAM
After an initial check process, the ignition control activates the gas valve and the signal to the spark generator for this to
activate the spark plug. A safety time period starts from this moment. The spark plug lights the flame in the burner and the
flame is detected by the flame detector. If there is no flame, the system repeats the process until it lights or after three
attempts, the system blocks, generating an ERROR.