ELECTRICAL CONVERSION from 400 c 3P+N+E to 230 V 3P+E
ELECTRICAL CONVERSION from 400 c 3P+N+E to 230 V 3P+EELECTRICAL CONVERSION from 400 c 3P+N+E to 230 V 3P+E
ELECTRICAL CONVERSION from 400 c 3P+N+E to 230 V 3P+E
This conversion is only valid for electric ovens, as GAS ovens are single-phase.
- To convert the oven electrically, release the three groups of cables (black, brown and
grey) from the Neutral terminal strip).
- When the three groups of cables have been released from the Neutral terminal strip, place
them on the R, S and T terminal strips, matching the colours, black, brown and grey
(black-black, brown-brown, grey-grey).
- After the electrical conversion, the Neutral terminal strip is no longer used.
400 Volt connection
3P+N+E
240 Volt connection
3P+E
Conversion
T
S
R
N
Neutral terminal strip
Group of black, brown and grey cables