DESCALING
DESCALINGDESCALING
DESCALING
WARGING!
WARGING!WARGING!
WARGING!
The descaling
The descalingThe descaling
The descaling
function is performed by the SAT. All the relevant safety measures for preventing
function is performed by the SAT. All the relevant safety measures for preventing function is performed by the SAT. All the relevant safety measures for preventing
function is performed by the SAT. All the relevant safety measures for preventing
accidents should be observed. Procedure involving chemical products.
accidents should be observed. Procedure involving chemical products.accidents should be observed. Procedure involving chemical products.
accidents should be observed. Procedure involving chemical products.
The chemical product used must have a phosphoric acid base
phosphoric acid base phosphoric acid base
phosphoric acid base at a concentration of 35 ÷ 40 %. It may contain an anti-
foaming agent. A chemical concentration of approximately 10 ÷ 15%
10 ÷ 15%10 ÷ 15%
10 ÷ 15% of the capacity should be used in the boiler. This
concentration depends on the degree of lime scale saturation and the effectiveness of the chemical product. Please refer to
the supplier for advice on the method of application.
When the over automatically detects an excess level of lime scale in the pipes, the text DESCALING flashes on the
display. The speed of the flash increases with the need for decaling, and when descaling is obligatory the message is
permanently lit and the boiler heating is blocked (at this point the oven only operates in convection mode).
Lime scale detection
Lime scale detectionLime scale detection
Lime scale detection
In any operating mode, if the TG probe reaches:
o 125 ºC The message “DESCALE
“DESCALE”“DESCALE
“DESCALE” is displayed in the upper text of the screen, and flashes every two seconds.
o 140 ºC The message “DESCALE
“DESCALE”“DESCALE
“DESCALE” is displayed in the upper text of the screen, and flashes every one second.
o 155 ºC The message “DESCALE
“DESCALE”“DESCALE
“DESCALE” is displayed in the upper text of the screen, and flashes every ½ second.
o 180 ºC The message DESCALE
“DESCALE”“DESCALE
“DESCALE” is displayed continuously in the upper text of the screen, and the oven only
operates in
Convection mode
.
Once the message “DESCALE
“DESCALE”“DESCALE”
“DESCALE” has been displayed, it will not disappear until descaling takes place, even though the
TG temperature falls or if the oven is switched off. The message reappears when the oven is switched on.
Procedure for descaling
Procedure for descalingProcedure for descaling
Procedure for descaling
Phase 1:
Phase 1:Phase 1:
Phase 1: VAC operates for 3 minutes
The message SPRAY
“SPRAY“SPRAY
“SPRAY
DESCALER”
DESCALER”DESCALER”
DESCALER” is displayed and the process waits until the message is confirmed. Undo the side
panel of the oven and access the steam generator. En los modelos ELECTRICOS
ELECTRICOSELECTRICOS
ELECTRICOS, undo the descaling nut and pour the
descaler in the steam generator. En los modelos a GAS
GASGAS
GAS soltar el conducto de vapor a mara e introducir el
desincrustante.
Phase 2:
Phase 2:Phase 2:
Phase 2: VDV operates until reaching the maximum level, the boiler fills with descaler and water.
Phase 3:
Phase 3:Phase 3:
Phase 3: CV operates until TG reaches 6C. When TG falls below 58 ºC, CV enters again until reaching 61ºC, this
continues for the period selected by the user. The display shows a countdown for the time remaining.
Phase 4:
Phase 4:Phase 4:
Phase 4: VAC operates for 3 minutes
Phase 5:
Phase 5:Phase 5:
Phase 5: VDV operates until reaching N.max.
Phase 6:
Phase 6:Phase 6:
Phase 6: VAC operates for 3 minutes.
Phase 7:
Phase 7:Phase 7:
Phase 7: VDV operates until reaching N.max.
Phase 8:
Phase 8:Phase 8:
Phase 8: Steam mode operates until TC reaches 95ºC.
If, during the descaling cycle, the operation is aborted or the oven is switched off, proceed as follows:
- If it has not reached phase 2 The cycle is ended
- If it has reached or exceeded phase 2 The cycle goes to phase 4.
- If it has reached phase 4The cycle goes to the phase in which it stopped