Connection diagrams
10.
358
Ref.1912
DDS
HARDWARE
· 352 ·
10.14 ACD/SCD compact system diagrams, CAN connection
F. H10/25
Compact system with CAN connection.
7
6
3
5
4
8
2
1
Speed Enable
Drive Enable
1
10
(Phoenix,
5.08mm)
X2
X2
Chassis
+24 V DC
KA4
KA3
DR.X
OK
+24 V DC
3
2
1
X1
L1
L2
L3
L1
L2
L1
L2
9
10
Gnd
7
6
3
5
4
8
2
1
Speed Enable
Drive Enable
1
10
(Phoenix,
5.08mm)
X2
X2
Chassis
+24 V DC
KA6
KA3
DR.Z
OK
+24 V DC
9
10
Gnd
3
2
1
X1
L1
L2
L3
L1
L2
L1
L2
L1
L2
L3
L1
L2
L3
Error Reset
+24 V DC
ON
Error Reset
3x400/460 V AC
2x400/460 V AC
3x400/460 V AC
2x400/460 V AC
COMPACT
DRIVE
MODULE
SCD 1.15
Z
FAGOR CNC
X
Ri
Re
L+
Ri
Re
L+
CAN L
SHIELD
CAN H
SELECT
NODE
SELECT
NODE
L-
L-
COMPACT
DRIVE
MODULE
SCD 1.15
2
3
4
2
1
0
1
0
1
Notes.
Compact modules do not have the System_Speed_Enable signals.
In this diagram, in spite of having CAN interface, electrical signals are used to activate the enables.