8
MOD.
AD-125 (HRS, SOFT)
CONNECTION
Fuse
protec.
Total
kW
Total
Amp.
Wire
Section
RC
(kW)
RT
(kW)
MB
(kW)
230V, 1N~
SIM
32 A
6,2 kW
26,7 A
3G 4 mm
2
4,5
1,1
0,6
40 A
8 kW
34,8 A
3G 6 mm
2
6
1,4
0,6
400V, 3N~
SIM
20 A
11,7 kW
18,7 A
5G 2,5 mm
2
9
2,1
0,6
230V, 3~
SIM
40 A
11,7 kW
30,5 A
4G 6 mm
2
9
2,1
0,6
CONEXION ELECTRICA DE FABRICA / CONNEXION ELECTRIQUE DU FACTORY /
FACTORY DEFAULT ELECTRICAL CONNECTION / FABRIK ELEKTRISCHER ANSCHLUSS /
CONNESSIONE ELETTRICA PREDEFINITA IN FABBRICA / FABRİKA AYARININ ELEKTRİK BAĞLANTISI
400V, 3N~,
SIM
, 11,7 kW,
18,7 A,
5G 2,5 mm
2
MOD.
AD-125 ECO
CONNECTION
Fuse
protec.
Total
kW
Total
Amp.
Wire
Section
RC
(kW)
RT
(kW)
MB
(kW)
230V, 1N~
16 A
2,7 kW
11,8 A
3G 1,5 mm
2
-
2,1
0,6
400V, 3N~
16 A
2,7 kW
5,7 A
5G 1,5 mm
2
-
2,1
0,6
230V, 3~
16 A
2,7 kW
7,9 A
4G 1,5 mm
2
-
2,1
0,6
CONEXION ELECTRICA DE FABRICA / CONNEXION ELECTRIQUE DU FACTORY /
FACTORY DEFAULT ELECTRICAL CONNECTION / FABRIK ELEKTRISCHER ANSCHLUSS /
CONNESSIONE ELETTRICA PREDEFINITA IN FABBRICA / FABRİKA AYARININ ELEKTRİK BAĞLANTISI
400V, 3N~,
SIM
, 2,7 kW,
5,7 A,
5G 2,5 mm
2