Technical Data
Dimensions in mm:
Installation opening L x P 1 550 x 470
2 550 x 470
3 750 x 470
BURNER
TYPE
MAX
OUTPUT
MIN
OUTPUT
G20
20mbar
G30
28-30mbar
G30
50mbar
Kw
Kw
Nozzle
Making
mm
Cons
M
3
/h
Cons
g/h
Cons
g/h
Small
Auxiliary
burner
1.00
0.35
0.72
0.095
73
73
Medium
Semi-rapid
Burner
1.75
0.65
0.97
0.167
127
127
Large
rapid
burner
3.0
1.0
1.15
0.286
218
218
Triple
flame
burner
3.80
1.9
1.35
0.362
277
277
Gas intake connection G1/2
Electricity supply 220-240v~50/60Hz
Instructions for the installation technician
CAUTION: This appliance must only be installed and used in rooms with
permanent ventilation to local standards.
Installation of the appliance and its connection to the electrical mains must
only be carried out by QUALIFIED PERSONEL.
Before any procedure, it is important to check that the appliance is
DISCONNECTED from the electrical mains. The Manufacturer declines all
responsibility for any damage arising from installation in breach of the
regulations in force or from failure to comply with the accident prevention
regulations.