0.3.4 Download log to USB 
Using the   key, the log can be downloaded to a USB flash drive. Every time a download is 
made,  a  folder  is  created  with  SerialNo_Date_Time_Log,  creating  a  unique  “.sts”  file  with  all  the 
information.  
In addition, different machine parameters are downloaded (Serial No, Model, Date, Time, Heating 
type, operation mode (OPL/Self-service), Start date and SW version) for subsequent loading in the Wash-
Control. 
Press   to return to the log screen. 
0.4 Configure alarms 
On the maintenance screen, select the   icon, and go to the alarm configuration screen. 
 
Press   to return to the initial SAT screen. 
  The following errors can be configured: 
0.4.1 E4: Maximum water level reached 
You can override this error by pressing  . Default Enabled. 
0.4.2 E3: Drainge failure / water in tub 
Press  the    key  to  modify  error  3,  drainage  failure.  The  time  after  which  the  error  is 
displayed on the screen can be configured. 
The error time can be configured. Range, from 5 to 30 minutes. The default time programmed is 
10 minutes.