EasyManua.ls Logo

Falcon G2844F - User Manual

Falcon G2844F
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
G2844F/G2845F
PREMIX
FRYERS
CAUTION: Read the instructions before
using the appliance
INSTALLATION, SERVICING
and USER INSTRUCTIONS
These appliances must be installed and serviced by a qualified person as stipulated by the Gas Safety
(Installation & Use) Regulations.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and
National Regulations in force at the time of installation. Particular attention MUST be paid to -
Gas Safety (Installation & Use) Regulations I.E.E. Regulations for Electrical Installations
Health And Safety At Work etc. Act Electricity at Work Regulations
Local and National Building Regulations
Fire Precautions Act
Detailed recommendations are contained in Institute of Gas Engineers published documents :
IGE/ UP/ 1, IGE/ UP/ 2, BS6173 and BS5440
These appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive for the
Countries, Gas Types and Pressures as stated on the data plate.
WARNING -
TO PREVENT SHOCKS, ALL APPLIANCES, GAS OR ELECTRIC, MUST BE EARTHED.
On completion of the installation, these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, the user instructions should be handed over to the user,
having
had a demonstration of the operation and cleaning of the appliance.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance
Contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the SERVICELINE contact
numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a
licenced waste handler. Units are designed to be dismantled easily and recycling of all material is
encouraged whenever practicable.
This equipment is ONLY FOR PROFESSIONAL USE, and shall be operated by QUALIFIED persons. It is the
responsibility of the supervisor or equivalent to ensure that users wear SUITABLE PROTECTIVE
CLOTHING and to draw attention to the fact that some parts will, by necessity, become VERY HOT and will
cause burns if touched accidentally.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000 Fax: 01438 369 900
T100742 Ref 6

Questions and Answers

  • U
    ubakerAug 7, 2025
    What to do if my Falcon G2844F has no power?
    • B
      Bethany MitchellAug 7, 2025
      If your Falcon Fryer isn't getting power, here are a few things to check: * Ensure the fryer is properly plugged into the outlet. * Verify that the circuit breaker hasn't tripped; if it has, reset it. * Confirm that power is being supplied to the unit. * If the 24V AC transformer is defective, consider replacing the transformer and/or controller.
  • A
    anthony89Aug 11, 2025
    Why is my Falcon G2844F Fryer not heating?
    • J
      joelortegaAug 11, 2025
      If your Falcon Fryer isn't heating up, consider the following: * Check the gas circuit for any issues. * A defective controller could be the cause, so consider replacing it. * Replace any defective parts in the gas circuit.
  • C
    Calvin HamptonAug 15, 2025
    What to do if my Falcon G2844F Fryer is reading the wrong temperature?
    • M
      Miss Deborah MathisAug 16, 2025
      If your Falcon Fryer displays an incorrect temperature, the temperature probe might be defective. Replace the temperature probe to resolve this issue.
  • J
    Jason EnglishAug 19, 2025
    What to do if 'PROB' is displayed on my Falcon G2844F Fryer?
    • G
      George StewartAug 20, 2025
      If 'PROB' is displayed on your Falcon Fryer, it could indicate a problem with the temperature probe. Here's what to do: * Ensure the probe is properly plugged in. * If the probe is plugged in, the temperature probe may be defective and require replacement.
  • L
    Lindsay JonesAug 25, 2025
    What to do if the filtration pump is not working on my Falcon G2844F Fryer?
    • K
      Kelsey HernandezAug 25, 2025
      If the filtration pump on your Falcon Fryer isn't working, consider these potential causes: * The oil suction pipe may be blocked; clean and thoroughly dry it. * The pipework may be blocked or incorrectly inserted into the quick release connections. Please refer to Action 2. * The oil might be too hot; allow it to cool before pressing the reset switch directly below the pump on the base panel.
  • T
    Timothy WarrenAug 28, 2025
    How to fix no sound on Falcon Fryer?
    • N
      nicoleleeAug 28, 2025
      If there's no sound coming from your Falcon Fryer, the speaker might be inoperable. In this case, you should replace the controller.
  • A
    Andrew ClaytonSep 2, 2025
    What to do if button doesn't work on Falcon G2844F Fryer?
    • T
      thomasbrianSep 2, 2025
      If a button on your Falcon Fryer isn't working, the key may be inoperable. You should replace the controller.

Falcon G2844F Specifications

General IconGeneral
BrandFalcon
ModelG2844F
CategoryFryer
LanguageEnglish

Related product manuals