SECTION 5 - TROUBLESHOOTING
and CRITICAL DIMENSIONS
5.1 TROUBLESHOOTING
G2845F
PROBLEM - No power.
Action:
a) Check power is being supplied to unit.
b) Check temperature limit thermostat has not tripped (Refer to Section 2.6).
G2844F
PROBLEM - No power
Cause: Circuit breaker off.
Solution: Check and reset.
Cause: Appliance not plugged in.
Solution: Plug cord in.
Cause: Defective 24V AC transformer.
Solution: Replace transformer and/or controller.
PROBLEM - No sound
Cause: Inoperable speaker.
Solution: Replace controller.
PROBLEM ā Button
Cause: Inoperable key.
Solution: Replace controller.
PROBLEM: PROB is displayed.
Cause: Defective temperature probe.
Solution: Replace temperature probe
Cause: Probe not plugged in
Solution: Plug probe in
PROBLEM: Reading Wrong Temperature
Cause: Defective temperature probe.
Solution: Replace temperature probe.
PROBLEM: Not Heating.
Cause: Check gas circuit.
Solution: Replace defective part.
Cause: Defective controller.
Solution: Replace controller.