Do you have a question about the FATEK FBs-4DA and is the answer not in the manual?
Model | FBs-4DA |
---|---|
Category | Controller |
Output Type | Analog |
Number of Outputs | 4 |
Channels | 4 |
Resolution | 12-bit |
Power Supply | 24V DC |
Communication Interface | RS-485 |
Protocol | Modbus RTU |
Output Range | 0-10V |
Isolation | 1500V |
Operating Temperature | 0°C to 55°C |
Storage Temperature | -20°C to 70°C |
Humidity | 5% to 95% (non-condensing) |
Weight | 150g |
Provides a comprehensive list of FBS PLC models with their specifications, categorized by type.
Lists key specifications of FBS-PLC main units, including execution speed, memory, and register types.
Illustrates the terminal block layouts and connection diagrams for various FBS-PLC main units.
Explains the single-unit system, block diagram, main units, and communication peripherals.
Details I/O expansion using Digital I/O and Numeric I/O through expansion units/modules.
Provides precautions for PLC installation to avoid interference and ensure proper mounting.
Provides essential precautions for construction and wiring, including wire gauge and separation.
Lists specifications for available AC power supplies, including voltage, consumption, and isolation.
Details specifications for 5VDC differential and 24VDC single-end inputs, including speeds and current.
Lists specifications for differential, transistor, relay, and TRIAC single-end output circuits.
Discusses protection methods for output components against surge currents and noise.
Lists essential inspections before powering on, including power type and circuit consistency.
Details the meaning of PLC LED indicators and basic troubleshooting steps for errors.
Illustrates the memory buffer organization in PLC and FBS-PACK, including SRAM and program areas.
Lists the types, symbols, ranges, and remarks for digital and register allocations (bits and words).
Categorizes function instructions into Basic and Advanced groups, detailing their purposes.
Explains Timer instructions (T0-T255), including time bases, preset values, and operation.
Details Counter instructions (C0-C255), including preset values, count up/down, and clear functions.
Covers Master Control (MC/MCE) and Skip (SKP/SKPE) instructions for managing program execution flow.
Explains instructions for table operations like data move, fill, shift, rotate, queue, stack, compare, and sort.
Details instructions for integer-to-float conversion, float-to-integer, arithmetic, and trigonometric functions.
Explains the concept of steps, their equivalence to machine movements, and the overall process structure.
Details the STP, FROM, TO, and STPEND instructions for defining and controlling steps in a sequence.