FBs-PLC User’s ManualHardware
Contents
Chapter 1Introduction of FATEK FBs Series PLC
1.1 Appearance of Main Unit ................................................................................................................. H1-1
1.2 Appearance of Expansion Unit/Module .......................................................................................... H1-2
1.3 Appearance of Communication Expansion Module ..................................................................... H1-4
1.4 List of FBs-PLC Models ................................................................................................................... H1-5
1.5 Specifications of Main Unit ............................................................................................................... H1-8
1.6 Environmental Specifications .......................................................................................................... H1-9
1.7 Connection Diagrams of Various Models ...................................................................................... H1-10
1.7.1 NC Control Main Unit (MN) ........................................................................................................................... H1-10
1.7.2 Basic/Advanced Main Unit (MA/MC) ........................................................................................................... H1-11
1.7.3 Digital I/O Expansion Unit .............................................................................................................................. H1-13
1.7.4 Digital I/O Expansion Module ........................................................................................................................ H1-14
1.7.5 High-Density Digital I/O Expansion Module ................................................................................................ H1-15
1.7.6 Numeric I/O Expansion Module .................................................................................................................... H1-15
1.7.7 Analog I/O Expansion Module ...................................................................................................................... H1-15
1.7.8 Temperature Input Module ............................................................................................................................ H1-16
1.7.9 AI/AO/Temperature Combo Module .......................................................................................................... H1-17
1.7.10 Expansion Power Module ......................................................................................................................... H1-17
1.7.11 Voice Output Module ................................................................................................................................... H1-17
1.7.12 Potential Meter Module .............................................................................................................................. H1-17
1.7.13 Load Cell Module ....................................................................................................................................... H1-17
1.7.14 Communication Module (CM) .................................................................................................................... H1-18
1.7.15 Communication Board (CB) ........................................................................................................................ H1-19
1.7.16 Analog Expansion Board ........................................................................................................................... H1-20
1.7.17 Simple HMI .................................................................................................................................................... H1-20
1.8 Drawings with External Dimensions ............................................................................................... H1-21
Chapter 2System Configuration
2.1 Single-Unit System of FBs-PLC ...................................................................................................... H2-1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the FATEK FBs-4PT and is the answer not in the manual?

FATEK FBs-4PT Specifications

General IconGeneral
ModelFBs-4PT
TypeTemperature Input Module
Input Points4
Power Consumption1.5W
Operating Temperature-10°C to 55°C
Storage Temperature-20°C to 70°C
Communication InterfaceRS-485
Thermocouple TypeK, J, E, S, T, R, B, N
RTD TypePT100
Resolution0.1°C
Sampling Rate100ms per channel
Isolation1500Vrms
Power Supply24 VDC
Input TypeThermocouple or RTD
Humidity5 to 95% (non-condensing)

Summary

Chapter 3 Expansion of FBS-PLC

3.1 I/O Expansion

Details the process and limits for expanding Digital and Numeric I/O points in an FBs-PLC system.

3.2 Expansion of Communication Port

Explains how to add communication ports using Communication Boards (CB) and Modules (CM).

Chapter 4 Installation Guide

Chapter 5 Power Supply Wiring, Power Consumption Calculation, and Power Sequence Requirements

5.1 Specifications and Wiring of AC Power Sourced Power Supply

Details specifications and wiring for AC power supplies used with FBs-PLC units.

5.2 Specifications and Wiring of DC Power Sourced Power Supply

Lists specifications and wiring instructions for DC power supplies for FBs-PLC.

5.3 Residual Capacity of Main/Expansion Unit & Current Consumption of Expansion Module

Provides data on power supply capacities and current draw for FBs-PLC modules.

5.4 Requirement of Power Sequence in Main Unit & Expansion Unit/Module

Explains the necessary power-up sequence for main and expansion units to ensure correct I/O detection.

Chapter 6 Digital Input (DI) Circuit

6.1 Specifications of Digital Input (DI) Circuit

Outlines specifications for 5VDC differential and 24VDC single-end digital input circuits.

Chapter 7 Digital Output (DO) Circuit

7.1 Specifications of Digital Output Circuit

Lists specifications for differential and single-end transistor/relay output circuits.

Chapter 8 Test Run, Monitoring and Maintenance

8.2 Test Run and Monitoring

Explains how to use the Disable/Enable feature for testing and monitoring I/O points.

8.3 LED Indicators on PLC Main Unit and Troubleshooting

Details the meaning of PLC indicators and common troubleshooting steps for errors.