INSTALLATION, OPERATION, AND SERVICE MANUAL
FOR THE
MODEL FBD550
FROZEN BEVERAGE DISPENSER
SPECIFICATIONS
DIMENSIONS
Width 17.0 inches (432 mm)
Depth 32.3 inches (820 mm)
Height (Standard Countertop Unit) 34.0 inches (864 mm)
Height (Optional Roll Around Unit/Stand) 68.0 inches (1727 mm)
WEIGHT
Shipping 395 pounds (179.2 kg)
Empty 318 pounds (144.2 kg)
Operational 345 pounds (156.5 kg)
WATER REQUIREMENTS
Minimum flowing pressure 30 PSIG (207.0 KPa)
Maximum static pressure 70 PSIG (483.0 KPa)
CARBON DIOXIDE (CO
2) REQUIREMENTS
Minimum pressure 70 PSIG (483.0 KPa)
Maximum pressure 75 PSIG (517.5 KPa)
NOTICE:
The information contained in this document is subject to change without notice.
FBD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMIT-
ED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. FBD shall not be liable for errors contained herein or for incidental consequential damages in connection with the
furnishings, performance, or use of this material.
This document contains proprietary information which is protected by copyright. All rights reserved.
© Copyright 2006 by FBD, all rights reserved.
This manual supersedes FBD Manual 24-0276-0003, dated 01/31/05.
Revision: 10-25-06
FBD Part Number: 24-0276-0003
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This manual must be read and understood before the installation and operation of this dispenser.
Check out the FBD web site:
www.fbdfrozen.com
FBD Partnership, LP
P.O. BOX 18597. SAN ANTONIO, TX 78218 USA
210-637-2800 FAX 210-637-2844 www.fbdfrozen.com
FBD TECHNICAL SUPPORT • 1-866-323-2777 • TECHNICAL SUPPORT FAX 1-210-637-2832

Table of Contents

Questions and Answers

  • H
    Heather JonesSep 10, 2025
    What causes low beater counts on the FBD Dispenser?
    • K
      kimberlybrownSep 12, 2025
      Low beater counts on your FBD Dispenser can be due to: * The chamber being frozen too hard or solid. * Lower motor control board failure. * Beater motor capacitor. * Beater motor problem. To address this: 1. Verify correct brix, Level Control, and Thaw/Freeze settings. Defrost the chamber, refill to 90%, and refreeze. 2. Replace the lower board. 3. Check the motor capacitor and replace it if necessary. 4. Replace the beater motor.
  • P
    Patricia RobinsonAug 22, 2025
    What to do if the FBD Dispenser is out of product?
    • M
      Mariah RobertsonAug 22, 2025
      If your FBD Dispenser displays an 'Out of Product' message, first, ensure that the water is turned on, the CO2 supply is not empty or turned off, and the syrup container is not empty and properly connected. Second, check all lines for crimps or restrictions. Then, check the pressure readouts (H2O, CO2, and Syrups) and adjust regulators if the pressure is not at 70-72psi. Finally, inspect all pumps and replace them if necessary.
  • A
    Adam DanielsSep 7, 2025
    How do I fix a brix sample valve leak on my FBD Dispenser?
    • C
      Christina MartinSep 7, 2025
      To fix a leaking brix sample valve on your FBD Dispenser: 1. Turn off the CO2, water, and disconnect the syrup. Depressurize by pressing the sample valve. Remove the C-clip from the bottom of the sample valve. 2. Remove the sample valve shaft, change the o-rings, and reinstall. 3. If the inside hole of the plastic header block is scratched or damaged, replace the upper header block.
  • D
    Dustin KiddSep 6, 2025
    What causes a noisy condenser fan in FBD Dispenser?
    • J
      Jennifer CombsSep 6, 2025
      A noisy condenser fan in your FBD Dispenser can be caused by: * The fan contacting the condenser, fan blade guard, or another part. * An unbalanced fan blade. * Loose fan bracket fasteners. To address this: 1. Remove the fan guard and adjust the fan up or down as required. Remove any obstructions as necessary. Reinstall the fan guard. 2. Remove the fan guard, slide the fan blade weights (on 3 blades) to balance the fan. Replace the fan if necessary. Reinstall the fan guard. 3. Tighten any loose fasteners.
  • M
    Mike MooreSep 4, 2025
    Why is the compressor on my FBD Dispenser running for a long time but not freezing?
    • B
      Brian McdonaldSep 4, 2025
      If the compressor on your FBD Dispenser runs for a long time but does not freeze, check the following: 1. Verify that the Return Temperature drops below 20°F. The Return Temperature should achieve 20°F within 7 to 25 minutes of startup (no drinks dispensed). 2. Ensure that airflow through the condenser is not blocked. Clear any blockage and clean the air filter. 3. If the hot gas valve is activated in Manual On/Off, select "Defrost Sol" in “Manual ON/OFF”; test the solenoid, then turn it off.
  • T
    Tammy CurtisSep 3, 2025
    What to do if the FBD Dispenser drink is too 'Wet' or 'Liquid'?
    • E
      Elizabeth WeissSep 3, 2025
      If the drink from your FBD Dispenser is too 'Wet' or 'Liquid': 1. Defrost the chamber, then ensure it is 90% full. 2. Clean or replace the CO2 check valve.
  • C
    Courtney RiveraSep 2, 2025
    How do I resolve solenoids continuously activated on FBD Dispenser?
    • M
      Mr. Ryan MontgomerySep 2, 2025
      If the solenoids on your FBD Dispenser are continuously activated: 1. In “Manual On/Off”, energize the solenoid on and off, checking for plunger movement and 24VAC at the coil. Clean or replace the solenoid, if necessary. 2. Test the solenoid relay on the Relay Board for 24VAC output and 5VDC relay coil input. Replace the Relay Board, if necessary. 3. Observe "Tank Pressure" readouts and check the corresponding transducer. Replace the transducer, if necessary.
  • L
    Lauren GardnerAug 30, 2025
    How do I fix solenoids not activating on my FBD Dispenser?
    • S
      Savannah PhelpsAug 30, 2025
      If the solenoids on your FBD Dispenser are not activating, you can try the following steps: 1. In “Manual On/Off”, energize the solenoid on and off, checking for plunger movement and 24VAC at the coil. Clean or replace the solenoid, if necessary. 2. Test the solenoid relay on the Relay Board for 24VAC output and 5VDC input. Replace the Relay Board, if necessary. 3. Ensure connections are clean and secure at P14 and the solenoid coils.
  • A
    Andrea SmithAug 29, 2025
    What causes a faulty tank pressure reading on FBD Dispenser LCD?
    • D
      donna02Aug 29, 2025
      A faulty tank pressure reading on the LCD of your FBD Dispenser is caused by a pressure transducer failure. Check the transducer and replace it if necessary.
  • A
    Amber KingAug 27, 2025
    How to troubleshoot low water pressure in FBD Dispenser?
    • E
      Evelyn NielsenAug 27, 2025
      To troubleshoot low or no water pressure in your FBD Dispenser: 1. Ensure the water is turned on and check for any line restrictions. 2. Verify that the CO2 is turned on and the "CO2 Press" readout is at 70-72 PSIG (482.6-496.4 KPa). 3. Check that the "H2O Pressure" readout is at 70-75 psi. Check the transducer and replace it if needed. 4. Check the water pump and replace it if necessary.