INSTALLATION, OPERATION, AND SERVICE MANUAL
FOR THE
MODEL FBD550
FROZEN BEVERAGE DISPENSER
SPECIFICATIONS
DIMENSIONS
Width 17.0 inches (432 mm)
Depth 32.3 inches (820 mm)
Height (Standard Countertop Unit) 34.0 inches (864 mm)
Height (Optional Roll Around Unit/Stand) 68.0 inches (1727 mm)
WEIGHT
Shipping 395 pounds (179.2 kg)
Empty 318 pounds (144.2 kg)
Operational 345 pounds (156.5 kg)
WATER REQUIREMENTS
Minimum flowing pressure 30 PSIG (207.0 KPa)
Maximum static pressure 70 PSIG (483.0 KPa)
CARBON DIOXIDE (CO
2) REQUIREMENTS
Minimum pressure 70 PSIG (483.0 KPa)
Maximum pressure 75 PSIG (517.5 KPa)
NOTICE:
The information contained in this document is subject to change without notice.
FBD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMIT-
ED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. FBD shall not be liable for errors contained herein or for incidental consequential damages in connection with the
furnishings, performance, or use of this material.
This document contains proprietary information which is protected by copyright. All rights reserved.
© Copyright 2006 by FBD, all rights reserved.
This manual supersedes FBD Manual 24-0276-0003, dated 01/31/05.
Revision: 10-25-06
FBD Part Number: 24-0276-0003
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This manual must be read and understood before the installation and operation of this dispenser.
Check out the FBD web site:
www.fbdfrozen.com
FBD Partnership, LP
P.O. BOX 18597. SAN ANTONIO, TX 78218 USA
210-637-2800 FAX 210-637-2844 www.fbdfrozen.com
FBD TECHNICAL SUPPORT • 1-866-323-2777 • TECHNICAL SUPPORT FAX 1-210-637-2832

Table of Contents

Questions and Answers

  • R
    Roger SullivanAug 27, 2025
    Why is my FBD Dispenser chamber filling even when turned off?
    • J
      jonescraigAug 27, 2025
      If the chamber of your FBD Dispenser continues to fill even when the unit is turned off, the issue might be: * Solution solenoid plunger sticking. * Solution solenoid energized. * Solution solenoid left “ON” in “Manual”. To resolve this: 1. In “Manual On/Off”, energize the solenoid and check for 24VAC at the coil. Clean or replace the solenoid, if necessary. 2. Test the solenoid relay on the relay board for 24VAC output and 5VDC relay coil input. Replace the Relay Board, if necessary. 3. In “Manual On/Off”, turn the solenoid off.
  • A
    arnoldrebeccaAug 25, 2025
    What to do if product does not flow freely from FBD Dispenser?
    • Z
      Zachary BurtonAug 25, 2025
      If the product from your FBD Dispenser does not flow freely or doesn't flow at all, you can try the following: 1. Inspect the CO2 check valve and clean or replace it. 2. In “Manual On/Off”, energize the CO2 and solution solenoid and check for 24VAC at the coil. Clean or replace the solenoid, if necessary. 3. Run a defrost cycle. If necessary, open and close the dispensing valve several times or run warm water over the valve. 4. Check water/syrup flow rates and brix and adjust, if necessary. Check the Level Control setting and adjust if necessary. Check the Thaw/Freeze settings and adjust if necessary. Defrost the chamber, ensure it is filled to 90%, then press "Run".