5.3.3 Read MAC Address
Format: AT+ADDR
Response: +ADDR=Param
Param: Modules MAC address (12 Bytes ASCII)
5.3.4 Read/Write Local Name
Format: AT+NAME {=Param1{, Param2}}
Param1: LE local name (1~29 Bytes ASCII, default: Feasycom)
Param2: MAC address suffix (0/1, default: 0)
(0) Disable suffix
(1)Enable suffix-XXXX (lower 4 bytes of MAC address)
Response: +NAME=Param
Description: Write local name if there are parameter, otherwise just
read current local
name
Example: Read current local name
<< AT+NAME
>> +NAME=Feasycom
>> OK
Example: Change modules local name to
ABC
<< AT+NAME=ABC
>> OK
Example: Change modules local name to ABC and enable suffix
<< AT+NAME=ABC,1
>> OK
5.3.5 Read/Write UART Baudrate
Format: AT+BAUD{=Param}
Param: Baudrate (1200/2400/4800/9600/19200/38400/57600/115200/
230400, default:115200)