EasyManua.ls Logo

Feasycom FSC-BT691 - Read;Write TX Power; Turn On;Off Low Power Mode

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Response: +BAUD=Param
Description: Modules baudrate will be changed immediately after received this command
5.3.6 Read/Write TX Power
Format: AT+TXPOWER{=Param}
Param: TX power (0~11, default:8)
Response: +TXPOWER=Param
Description: If there is a parameter behind the command, the TX power
is written, if not,
read the TX power.
AT+TXPOWER=0 Correspond to: -19.5dbm
AT+TXPOWER=1 Correspond to: -13.5dbm
AT+TXPOWER=2 Correspond to: -10.5dbm
AT+TXPOWER=3 Correspond to: -7.0dbm
AT+TXPOWER=4 Correspond to: -5.0dbm
AT+TXPOWER=5 Correspond to: -3.5dbm
AT+TXPOWER=6 Correspond to: -2.0dbm
AT+TXPOWER=7 Correspond to: -1.0dbm
AT+TXPOWER=8 Correspond to: 0dbm
AT+TXPOWER=9 Correspond to: 1.0dbm
AT+TXPOWER=A Correspond to: 1.5dbm
AT+TXPOWER=B Correspond to: 2.5dbm
Example: Read currently TX power
<<
AT+TXPOWER
>> +TXPOWER=8
>> OK
Example: Setting currently TX power
<<
AT+TXPOWER=11
>> OK
5.3.7 Turn On/Off Low Power Mode
Format: AT+LPM{=Param}
Param: Low Power Mode (0/1, default: 0)