8.2. Installation notes
Be aware of the following possible environmental factors when installing an ID CPR50.10-E into
another device :
Effects from nearby metal objects
Detuning of the integrated antenna
Impaired communication of the antenna’s magnetic field
EMC effects on cables
Impaired communication between reader and transponder
EMC effects from magnetic fields
Impaired communication between reader and transponder
8.2.1. EMC effects on cables
In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can
result in impairment of the communication between the reader and transponder.
When installing an ID CPR50.10-E into another device, be sure therefore that a clean, noise-free
power supply is used.
8.2.2. EMC effects from magnetic fields
The communication principle of RFID- Technology is based on the modulation of electromagnetic
fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on
the reader function.
Sources of such magnetic interference fields include coils within a primary or secondary switching
power supply.