Do you have a question about the Fender SPL-6000P and is the answer not in the manual?
stereo continuous sine wave output power into 8 Ω | 150 W each channel |
---|---|
stereo continuous sine wave output power into 4 Ω | 300 W each channel |
mono bridge output power into 16 Ω | 300 W |
mono bridge output power into 8 Ω | 600 W |
single channel driven output power into 8 Ω | 179 W |
single channel driven output power into 4 Ω | 312 W |
power bandwidth | 10 Hz to 68 kHz |
---|---|
frequency response | +0 -3dB; 5 Hz to 68 kHz |
rise time | Less than 5.2 µSec |
slew rate | Greater than 13.5 V/µSec |
total harmonic distortion | Less than 0.03% |
hum and noise broad band | 95 dB |
---|---|
hum and noise IEC A Weight | 102 dB |
damping factor 5 Hz to 20 kHz | Greater than 30 |
damping factor 1 kHz | Greater than 175 |
input impedance | 33 kΩ |
channel separation | Greater than 65 dB |
---|---|
sensitivity stereo mode | +1.8 dBV (1.23V) |
sensitivity bridged mode | +1.8 dBV |
cooling | Two speed fan |
---|---|
power requirements | 1000W |
status indicators | Peak LED (red), Power LED (green) |
gain controls | Continuously variable attenuator, one per channel |
mode switching | Stereo-Mono Bridge, Stereo-Dual Mono, two push button switches |
weight | 11.3 kg |
---|---|
height | 8.9 cm |
width | 48.3 cm |
depth | 38 cm |
Critical safety precautions to reduce risk of fire or shock hazard.
Warnings regarding minimum load impedance for stereo and bridged modes.
Guidelines for connecting the AC power cord and replacing the external fuse.
Warnings against using coiled guitar cords for speaker connections.
Advice on AC power source requirements and voltage drop effects.
Detailed technical specifications for output power, bandwidth, and distortion.