Plain end/spiral blades
• Remove the three screws and the cover on the left
side of the saw.
• Insert the blade through the table slot and attach the
adaptor to the lower end.
• Assemble the blade adaptor onto each end of the
blade; tighten the Allen bolts equally with the wrench
so the blade is square in the middle of the adaptor.
Ensure the small lugs on the adaptor barrel facing
inwards towards the middle of the blade; these lugs
locate in the depressions on the blade holders.
• Make sure the saw teeth face downwards towards
the saw table.
• Locate the lower adaptor in the lower blade holder
then pull the blade upwards and locate the upper
adaptor in the upper blade holder.
• Reinstall the left side cover and tighten screws.
• Adjust blade tension (6), safety shield and dust blo-
wer.
ADJUSTING THE ANGLE OF THE SAW
TABLE
Do not use this machine without the table moun-
ted.
Ensure the saw is switched OFF and unplugged
from mains.
Refer to illustration.
• Loosen the quadrant thumbscrew and tilt the table to
required angle.
• Tighten thumbscrew securely.
THE DUST BLOWER
The saw has a dust blower to clear sawdust /debris from
the table during use.
Be aware the saw can produce fine dust, which may
be hazardous to your health.
Always wear appropriate personal protection equipment. A
suitable dust mask and goggles are essential.
Ferm 10
ENVIROMENT
Recycle the packaging according to the identification
marks on it.
At the end of the product or its accessories life please
recycle where facilities exist. Phone the Helpline for cur-
rent advice on recycling.
Helpline
For any questions relating to operational or safety
matters contact:
Ferm Customer Helpline on: 0115 966 1199
Monday-Friday 8am – 6pm
Saturday 9am – 1 pm
GUARANTEE
The guarantee conditions can be found on the separately
enclosed guarantee card.
As sole responsible party, we declare that this product
corresponds to the following norms or normative
documents:
EN61029-1, EN55014-1, EN55014-2,
EN61000-3-2, EN61000-3-3
in accordance with the stipulations of the guidelines:
98/37/EEC
73/23/EEC
89/336/EEC
as from 01-09-2000
GENEMUIDEN NL
W. Kamphof
Quality department
CE
ı
DECLARATION OF CONFORMITY
(
UK
)
9 Ferm