EasyManua.ls Logo

Ferroli DOMIproject F 32 User Manual

Ferroli DOMIproject F 32
56 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
5
cod. 3540R780 — 02/2012 (Rev. 00)
D
DOMIproject F 24 - F 32
195
85 115 115 85
700
400
764
677
161161
87
161
Ø110÷120
60 60 86 95
F 32
95
166
67
115
91 127
700
400
110 85
763
700
63
Ø110 ÷ 120
60 61 59 80,5
145
F 24
230
330
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
KULLANMA, KURULUM VE BAKøM TALIMATLAR
ø
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
INSTRUCğIUNI DE UTILIZARE, INSTALARE ùI ÎNTRETINERE
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ
ȱɇɋɌɊɍɄɐȱə Ɂ ȿɄɋɉɅɍȺɌȺɐȱȲ, ɆɈɇɌȺɀɍ ɌȺ ɈȻɋɅɍȽɈȼɍȼȺɇɇə
Question and Answer IconNeed help?

Do you have a question about the Ferroli DOMIproject F 32 and is the answer not in the manual?

Ferroli DOMIproject F 32 Specifications

General IconGeneral
CategoryBoiler
TypeCombi
MountingWall-mounted
Heat output32 kW
FuelNatural Gas / LPG
Nominal output32 kW
Weight32 kg
Max working pressure3 bar
IgnitionElectronic
Heat exchanger materialCopper
NOx emissionsClass 5
Electrical protection ratingIPX4D

Summary

General Instructions

Operating Instructions

Introduction to DOMIproject F 24 - F 32

Details the DOMIproject F 24 - F 32 as a high-efficiency heat generator for heating and domestic hot water production.

Control Panel and Operation

Describes the boiler's control panel, including adjustment knobs and operational procedures like ignition and shutdown.

System Water Adjustment

Guidance on adjusting system water pressure to the correct level, typically 1.0 bar when cold.

Installation

General Installation Guidelines

Emphasizes that installation must be performed by qualified personnel according to regulations and manual instructions.

Plumbing Connections

Details the necessary plumbing connections for the boiler, including safety valve discharge and system pipes.

Electrical Connections

Terminal Block Access and Thermostat

Details access to the terminal block and important safety warnings for room thermostat connection.

Fume Pipes and Ventilation

Service and Maintenance

Adjustments and Gas Conversion

Procedures for adjusting the boiler, including gas conversion and setting the correct gas type.

TEST Mode Activation

Instructions on how to activate and deactivate the TEST mode for boiler diagnostics and power checks.

Boiler Startup Procedure

Burner and Heating Power Adjustments

Ignition Power Adjustment

Instructions for adjusting the ignition power level for the boiler, using the TEST mode.

Troubleshooting Guide

Technical Data and Characteristics

Related product manuals