S.p.A.
8
SUN
CHOOSING THE INJECTOR
The injector must be chosen according to the power rating of the boiler flue, remembering that heating
oil has a heat value (N.H.V.) of 10200 kcal/Kg. The chart gives the flow rate or consumption in Kg/h and
kW of heating oil according to the size of the injector (in GPH) and the pump pressure (in bar). When the
burner has a preheater, the effective capacity will be about 10% lower than the values in the chart.
Injector
G.P.H.
0,40
0,50
0,60
0,65
0,75
0,85
1,00
1,10
1,20
1,25
1,35
1,50
1,65
1,75
2,00
2,25
2,50
3,00
1,27
1,59
1,91
2,07
2,38
2,70
3,18
3,50
3,82
3,97
4,29
4,77
5,25
5,56
6,30
7,15
7,95
9,54
7
1,36
1,70
2,04
2,21
2,55
2,89
3,40
3,74
4,08
4,25
4,59
5,10
5,61
5,95
6,80
7,65
8,50
10,20
89
1,44
1,80
2,16
2,34
2,70
3,06
3,61
3,97
4,33
4,50
4,87
5,41
5,95
6,31
7,21
8,15
9,01
10,82
1,52
1 ,90
2,28
2,47
2,85
3,23
3,80
4,18
4,56
4,75
5,13
5,70
6,27
6,65
7,60
8,55
9,50
11,40
10
1,59
1,99
2,39
2,59
2,99
3,39
3,99
4,38
4,78
5,00
5,38
5,90
6,58
6,98
7,97
8,97
9,97
11,96
11
1,67
2,08
2,50
2,71
3,12
3,54
4,16
4,58
5,00
5,20
5,62
6,24
6,87
7,29
8,33
9,37
10,41
12,49
12
1,73
2,17
2,60
2,82
3,25
3,68
4,33
4,77
5,20
5,40
5,85
6,50
7,15
7,58
8,67
9,75
10,83
13,00
13
1,80
2,25
2,70
2,92
3,37
3,82
4,50
4,95
5,40
5,60
6,07
6,75
7,42
7,87
8,99
10,12
11,24
13,49
14
1,86
2,33
2,79
3,03
3,49
3,96
4,65
5,12
5,59
5,80
6,28
6,98
7,68
8,15
9,31
10,47
11,64
13,96
15 17
1,98
2,48
2,97
3,22
3,72
4,21
4,96
5,45
5,95
6,20
6,69
7,43
8,18
8,67
9,91
11,15
12,39
14,87
16
1,92
2,40
2,88
3,12
3,61
4,09
4,81
5,29
5,77
6,00
6,49
7,21
7,93
8,41
9,61
10,85
12,02
14,42
6
1,18
1,47
1,77
1,91
2,2
2,5
2,94
3,24
3,53
3,68
3,97
4,42
4,86
5,15
5,89
6,62
7,36
8,83
Pump pressure kg/cm
2
Flow rate at injector outlet kg/h

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ferroli SUN Series and is the answer not in the manual?

Ferroli SUN Series Specifications

General IconGeneral
ModelSUN Series
CategoryBurner
ControlElectronic
DimensionsVaries by model
EfficiencyUp to 93%
NOx Emissions< 70 mg/kWh (Class 5)

Related product manuals