What to do if extraneous light strikes the photoresistance in Ferroli Burner?
- JJulie Reyes DVMJul 28, 2025
If extraneous light is affecting the photoresistance in your Ferroli Burner, the solution is to eliminate the source of the extraneous light.
What to do if extraneous light strikes the photoresistance in Ferroli Burner?
If extraneous light is affecting the photoresistance in your Ferroli Burner, the solution is to eliminate the source of the extraneous light.
Why is the pipe pressure adjustment incorrect in Ferroli Burner?
If the pipe pressure adjustment is incorrect in your Ferroli Burner, it could be due to a damaged fan motor, in which case you should replace it. Alternatively, the fan might be dirty, so try cleaning it.
How to fix no ignition shutdown in Ferroli SUN P7 Burner?
If your Ferroli Burner experiences no ignition shutdown, this could be due to a dirty combustion head. If so, empty and clean it. Another cause might be a blocked pellet feed duct. In this case, free it, ensure the combustion head isn't clogged, and empty it if needed.
What to do if Ferroli Burner shows pressure transducer fault?
If you're experiencing a pressure transducer fault (disconnected) in your Ferroli Burner, it may be due to disconnected wiring. Check the wiring and replace the sensor if necessary. The issue may also be due to a damaged sensor.
Why Ferroli Burner shows boiler shell probe fault?
If you encounter a boiler shell probe fault (if enabled) in your Ferroli Burner, the wiring may be shorted. In this case, check the wiring or replace the sensor. The wiring may also be disconnected.
Introduces the SUN P7 pellet burner, highlighting its design, technology, reliability, and quality.
Details the components and functions of the burner's control panel with a key.
Explains the steps involved in lighting the burner, including initial display messages.
Guides on setting the clock and selecting operating modes (Automatic, Manual On, Manual Off).
Details how to modify the pre-set weekly programme for heating control.
Explains automatic operation, shutdown conditions, and room requirements for the burner.
Outlines general rules for unit usage, modifications, and professional installation requirements.
Covers placement, room requirements, fixing the burner, and electrical connections.
Details the multipole terminal block, required connections, and electrical safety precautions.
Advises on fuel quality, pellet loading activation, and burner lighting during loading.
Describes three methods for managing burner lighting (default, internal clock, or contact).
Outlines checks before lighting, burner lighting steps, and burner setting adjustments.
Details annual maintenance tasks, including casing opening and burner disassembly.
Explains the self-diagnosis system, fault codes, and solutions for common burner issues.
Provides detailed dimensional drawings and measurements of the burner unit.
Shows a general view of the burner with numbered components and a key.
Lists key technical data such as heating capacity, fuel delivery, power, and weight.
Presents the electrical wiring diagram for connecting the burner and its components.