Safety
1.1 Important user information
Identification of dangers and notes on how to avoid them:
WARNING
Dangers which could lead to death or serious injuries.
CAUTION
Dangers which could lead to minor injuries or to serious material damage.
Other symbols:
NOTICE
Material damage or loss of function
Recommendation or tip
ENVIRONMENT
Information on environmentally friendly use
Link to accessories
è
www.festo.com/catalogue
1.2 General safety instructions
WARNING
Non-observance of safety instructions can result in death, serious injuries or
major material damage.
The safety instructions must be observed.
NOTICE
Electronics modules include electrostatically sensitive devices.
Incorrect handling can cause damage to the electronics modules.
Observe the handling specifications for electrostatically sensitive devices.
Discharge static electricity from your body before assembling or disassembling
modules to protect the modules.
NOTICE
To ensure compliance with the intended use:
Every output channel that is in use must be switched at least once a week.
If test pulses are switched off:
Every output that is in use must be switched at least once a day.
NOTICE
To ensure compliance with the safety level:
Specify that every output channel in use must be switched on for more than 1
minute at a time for every 8 hours of operation.
The operating time begins when the output module is first switched on.
NOTICE
Use a maximum of 2 output channels in a common safety pilot circuit.
Observe the regulations for electrical power supply (Protective Extra-Low
Voltage, PELV) to CPX terminals in the system description CPX-SYS-…
è
www.festo.com/sp.
1.3
Intended use
The output module CPX-FVDA-P2 is intended for use as a shut-off module for the
safe shutdown of connected consumers (safety function) if the following condition
is met:
The connected consumers are switched to a safe state when the safety shut-
down takes place.
Product versions
The output module CPX-FVDA-P2 is available in three versions
è
Tab. 4 Permissible components:
Version 1
in combination with certain manifold and interlinking blocks of the CPX terminal
Version 2
as part of the pneumatic interface VABA-S6-1-X...-F1-CB of the valve terminal
VTSA-F-CB
Version 3
as part of the pneumatic interface VABA-S6-1-X...-F2-CB of the valve terminal
VTSA-F-CB
Safety function
The safety function is achieved through dual-channel, P- and M-side disconnec-
tion of the load voltage supply for U
VAL
valves:
Version 1
Disconnection of the load voltage supply for U
VAL
valves of the CPX terminal:
output channel CH0 of the module.
Output channel CH0 is used to supply valve terminal pneumatic modules in
the CPX terminal fitted on the right-hand side.
Disconnection of the two outputs provided through the connection tech-
nology of the module: output channel CH1 and CH2 of the module, also
supplied via the load voltage supply for U
VAL
valves.
In addition, the unswitched load voltage supply U
VAL
is made available through
the connection technology of the module as operating voltage for the external
components (24 V DC auxiliary supply).
Version 2
Disconnection of the three internal safe voltage zones: CH0, CH1, CH2.
Version 3
Disconnection of the two internal safe voltage zones: CH0, CH1.
Disconnection of the safe output provided through the connection tech-
nology of the pneumatic interface: CH2.
The voltage zones can be disconnected independently of each other in an
electrically safe manner.
The output channels of the output module CPX-FVDA-P2 each form a safety circuit
with their connected consumers.
Information about the power supply for the CPX terminal
è System description
CPX-SYS-...
Range of application
The output module CPX-FVDA-P2 is a product with safety-related functions,
intended for mounting in machines or automation systems and is to be used
as follows:
in excellent technical condition
in its original condition, without unauthorised modifications
exclusively in the configurations stated in the CPX-FVDA-P2-... description
within the limits of the product defined by the technical data
è
7 Technical data
in an industrial environment
NOTICE
Note that the safety limits of the output module are also its physical limits.
1.4 Rules for product configuration
The output module CPX-FVDA-P2 may only be operated in Festo CPX terminals
of the variant CPX-M-... or in pneumatic interfaces for the valve terminal VTSA-F-
CB-….
Comply with all technical operating limits
è
7 Technical data. Otherwise, mal-
functions can occur.

Other manuals for Festo CPX-FVDA-P2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-FVDA-P2 and is the answer not in the manual?

Festo CPX-FVDA-P2 Specifications

General IconGeneral
BrandFesto
ModelCPX-FVDA-P2
CategoryControl Unit
LanguageEnglish

Related product manuals