EasyManua.ls Logo

Festo CTEU-PB - Page 95

Festo CTEU-PB
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Diagnostics
3-15
Festo P.BE-CTEU-PB-OP+MAINT-EN en 1208NH English
Bit7;6fixedat1;0
5
1230467
Bit
Byte 1:
Module number of t he channel-related dia-
gnostics
Module number 0 3 (0: base CTEU-PB)
01
5
1230467
Bit
Byte 2:
module type
Moduletype0...5(fixedat0)
Input/output
0; 0 = reser ved 1; 0 = output
0; 1 = input 1; 1 = input/output
5 1230467
Bit
Byte 3:
type of diagnostics
Error type (see Tab. 3/11)
Data format of the channel:
0; 0; 0 = reserved 1; 0; 0 = 1 byte
0; 0; 1 = 1 bit 1; 0; 1 = 1 word
0; 1; 0 = 2 bits 1; 1; 0 = 2 words
0; 1; 1 = 4 bits 1; 1; 1 = reserved
0
0
0
00
0
Fig. 3/4: Channel-related diagnostics: byte 1 ... 3