Crucial guidelines for safe operation, handling, and environment of the VPPM regulator.
Specifies the regulator's application in industrial environments and its primary function.
Mandates qualified personnel with specific skills for product maintenance and operation.
Describes how the regulator controls pressure proportionally to a specified setpoint.
Illustrates the physical components and connections of the VPPM regulator.
Explains the status LEDs and control buttons on the VPPM device.
Instructions for attaching the VPPM regulator to a wall surface.
Steps for mounting the VPPM regulator onto a standard H-rail.
Procedure for mounting the VPPM regulator onto a manifold block.
Details on connecting compressed air and tubing to the VPPM regulator.
Guidelines for safe electrical connections using PELV circuits.
Defines the assignment of pins to wire colors and port identifications.
Steps for initial setup, including setpoint signals and parameter selection.
Lists recommended parameter sets for different pneumatic configurations.
Identifies LED status, possible causes, and remedies for common malfunctions.
Provides specifications for materials, weight, and general characteristics.
Details electrical specifications such as voltage, current, and resistance.
Crucial guidelines for safe operation, handling, and environment of the VPPM regulator.
Specifies the regulator's application in industrial environments and its primary function.
Mandates qualified personnel with specific skills for product maintenance and operation.
Describes how the regulator controls pressure proportionally to a specified setpoint.
Illustrates the physical components and connections of the VPPM regulator.
Explains the status LEDs and control buttons on the VPPM device.
Instructions for attaching the VPPM regulator to a wall surface.
Steps for mounting the VPPM regulator onto a standard H-rail.
Procedure for mounting the VPPM regulator onto a manifold block.
Details on connecting compressed air and tubing to the VPPM regulator.
Guidelines for safe electrical connections using PELV circuits.
Defines the assignment of pins to wire colors and port identifications.
Steps for initial setup, including setpoint signals and parameter selection.
Lists recommended parameter sets for different pneumatic configurations.
Identifies LED status, possible causes, and remedies for common malfunctions.
Provides specifications for materials, weight, and general characteristics.
Details electrical specifications such as voltage, current, and resistance.
| Voltage supply | 24 V DC |
|---|---|
| Protection class | IP65 |
| Operating pressure | 0.2 to 0.8 MPa |
| Electrical connection | M12 plug connector |
| Operating medium | Compressed air |
| Medium temperature | -10 to +60 °C |
| Number of valves | 1 |
| Operating pressure range | 0.2 to 0.8 MPa |
| Type | Proportional pressure regulator |