15
OTHER
Programming
Items
Factory set
Default
Programming Range
(display)
Notes
Error Codes
• Display Errors (Codes)
1:
2:
3:
Chart is below
• Reset Errors
(Reset)
Reset
|_______________[]____|
YES NO
!!Errors must be
corrected and cleared!!
Copy
Program
• From SD to B.
SDÆ Brewer
SDÆ Brewer
|________________[]____
YES NO
Setup upload
------------------------------------------------------------------------
----
Please insert SD card with
the setup data!
• From B to SD
BrewerÆ SD
BrewerÆ SD
|________________[]____|
YES NO
Setup download
------------------------------------------------------------------------
----
Please insert SD card with
sufficient space
(≥2GB)
Upload Logo
Upload Logo
UPLOAD LOGO
Are you sure
|________________[]____|
YES NO
Please insert SD
card with logo file!
Res to
Factory
Reset to default
Reset to Default
Are you sure
|________________[]____|
YES NO
Completely
overwrites all user
setup, incl. user logo.
All Counters
Counters
• Display
Counters
-OR-
• Reset
Counters
Counters
Display Total
Counters
Left Brews
Left Brew activated
Left Brew [liters]
Left Bypass Activated
Left Bypass [liters]
Right Brews
Right Brew activated
Right Brew [liters]
Right Bypass Activated
Right Bypass [liters]
Fill valve Activated
Fill Valve [liters]
Heater Activated
Heater “on” time
Touch To Return
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Resetting will
restart counter
from zero
• Reset
Counters
Reset All
Counters
Reset All Counters
Are you sure
|________________[]____|
YES NO
Firmware
• Firmware
Version
-Software type
Firmware Version
SW ver. 1.0.2A
HW ver
BL ver.1.0.1
QP ver. 4.5.01
Displays firmware
version
• Update
Firmware
UPDATE
UPDATE
|________________[]____|
YES NO
Firmware upload
------------------------------------------------------------------------
----
Please insert SD card with
the firmware file!
ERROR CODES
Error code 50: Shorted temperature probe
Error code 51: Open temperature probe
Error code 100: Initial Fill Error. Initial fill time was more than 4 minutes after power up.
Error code 101: Error on refill
Error code 102: Unwanted fill; possible leak
Error code 103: Liquid level probe fault
Error code 201: Heater open, high limit thermostat, or Solid State Relay (SSR) fault