3.15.4 Hold type codes (P2000 Only)
Programmer parameter code I (Hold type) uses coded data of the following form.
DATA FIELD
HOLD TYPE
0000 NO INTERNAL HOLD
0005 HOLD ON RAMPS, ABOVE SETPOINT ONLY
0006 HOLD ON RAMPS, BELOW SETPOINT ONLY
0007 HOLD ON RAMPS, ABOVE AND BELOW SETPOINT
0009 HOLD ON DWELLS, ABOVE SETPOINT ONLY
0010 HOLD ON DWELLS, BELOW SETPOINT ONLY
0011 HOLD ON DWELLS, ABOVE AND BELOW SETPOINT
0013 HOLD ON RAMPS & DWELLS, ABOVE SETPOINT ONLY
0014 HOLD ON RAMPS & DWELLS, BELOW SETPOINT ONLY
0015 HOLD ON RAMPS & DWELLS, ABOVE AND BELOW SETPOINT