12 13
ADVANCED PARAMETERS SPECIFICATIONS
23. Key Pressed 2 times – value of SWITCH ON command sent to
3rd association group
This parameter denes value of SWITCH ON command sent to devices
in 3rd association group after a double click.
Available settings: 1-255 - sent value
Default setting: 99 Parameter size: 2 [bytes]
24. Key Pressed 3 times – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after a triple click.
Available settings: 0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately
Default setting: 0 Parameter size: 1 [byte]
25. Key Pressed 3 times – value of SWITCH ON command sent to
3rd association group
This parameter denes value of SWITCH ON command sent to devices
in 3rd association group after a triple click.
Available settings: 1-255 - sent value
Default setting: 255 Parameter size: 2 [bytes]
29. Key Held Down – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after holding the button down.
Available settings: 0 - no action
1 - START LEVEL CHANGE UP (brightening)
2 - START LEVEL CHANGE DOWN (dimming)
3 - START LEVEL CHANGE UP/DOWN (brighten-
ing/dimming) – alternately
Default setting: 3 Parameter size: 1 [byte]
30. Alarm frame triggers
Parameter determines which actions result in sending alarm frames
to 4th association group.
Available settings: 1 - Key Pressed 1 time
2 - Key Pressed 2 times
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key Held Down
64 - Key Released
Default setting: 127 (all) Parameter size: 1 [byte]
NOTE
Values of parame-
ter 30 may be com-
bined, e.g. 1+2=3
means that alarm
frames will be sent
after pressing the but-
ton once or twice.
Battery type:
Battery life:
Operating temperature:
EU standards compliance:
Radio protocol:
Radio frequency:
Range:
Dimensions
(diameter x height):
ER14250 ½AA 3.6V
est. 2 years (with default settings and
max. 10 pushes per day)
0 - 40°C (32 - 104°F)
RoHS 2011/65/EU
R&TTE 1999/5/EC
Z-Wave (500 series chip)
868.4 or 869.8 MHz EU;
908.4, 908.42 or 916.0 MHz US;
921.4 or 919.8 MHz ANZ;
869.0 MHz RU;
up to 50m (164 ft) outdoors
up to 40m (131 ft) indoors
(Depending on terrain and building
structure)
46 x 34 mm
(1.81" x 1.34")
#7: Specications
CAUTION
Using batteries other
than specied may
result in explosion.
Dispose of properly,
observing environ-
mental protection
rules.
NOTE
Radio frequency of
individual device
must be same as your
Z-Wave controller.
Check information
on the box or consult
your dealer if you are
not sure.