18
ADVANCED PARAMETERS
76. Alarm signalization reactivation period
Parameter determines a time period after which an alarm will be turned
back on (in case it was turned o by parameter 75 setting). It will also
resend commands to 2nd and 3rd association groups as if the alarm
was detected again.
Available settings: 0 - alarm reactivation inactive
1-65535 - time in seconds
Default setting: 0 Parameter size: 4 [bytes]
77. Flood sensor functionality turned o
Allows to turn o the internal ood sensor. Tamper and built in tem-
perature sensor will remain active.
Available settings: 0 - Default ood sensor operation (ood detec-
tion, reactions)
1 - Built-in ood sensor TURNED OFF (does not
change its state in the main controller, does
not send alarm notications nor turn on/o
commands to 2nd/3rd association groups with
ood state changes. Always visible in the main
controller as turned o)
Default setting: 0 Parameter size: 1 [byte]
78. Associations in Z-Wave network security mode
This parameter denes how commands are sent in specied associa-
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
network security mode. It does not apply to 1st “Lifeline group.
Available settings: 0 - none of the groups sent as secure
1 - 2nd group ”Control” sent as secure
2 - 3rd group ”Alarm” sent as secure
4 - 4th group Tamper sent as secure
Default setting: 7 Parameter size: 1 [byte]
NOTE
In case a time period
set in parameter 76 is
shorter than the one
specied in parameter
75, the device will not
quiet the alarm, it will
remain active.