7
DIAGRAMS AND CONNECTION
Connecting the FIBARO Flood Sensor in a manner
inconsistent with manual may cause risk to health, life or
material damage.
!
Notes for the diagrams and probes marking:
+12V - 12 / 24 VDC positive terminal
GND - negative (ground) terminal
ALARM NC - potential-free ood sensor terminals (for wired systems)
TAMP NC - potential-free tamper terminals (for wired systems)
SENS1, SENS2 - ood sensor electrodes’ terminals
TMP - tamper button (used to add/remove the device)
ALARM
NC
TAMP
NC
SENS 1
SENS 2
+ 12
GND
TMP
#4: Diagrams and connection
1 2
3
12/24 VDC
ADAPTER
ALARM
NC
TAMP
NC
SENS 1
SENS 2
+ 12
GND
+
-
TMP
Connection to a constant power source:
NOTE
The TMP button has
two functions:
1. Adding / Removing
the device to / from
the Z-Wave network,
2. Tamper contact
for 4th Association
Group. When a sen-
sor is added to the
Z-Wave network, cov-
er open alarm may be
activated (according
to parameter 74 set-
tings).
i
CAUTION
Connect while observ-
ing wiring diagram
shown in this manual
only. Incorrect wiring
may be dangerous or
result in the device
breakdown.
!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO FGFS-101 and is the answer not in the manual?

FIBARO FGFS-101 Specifications

General IconGeneral
TypeFreestanding
PurposeIndoor/outdoor
Accuracy0.5 °C
Connectivity technologyWireless
Humidity measuring range0 - 40 %
Battery typeCR123A
Number of batteries supported1
Storage temperature (T-T)- °C
Built-in displayNo
Weight and Dimensions IconWeight and Dimensions
Width72 mm
Height28 mm

Related product manuals