Group Number
Maximum Nodes
Description
1
1
Lifeline
2
5
Roller Shutter
3
5
Slats position control
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in
the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For
example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may needed to be
given as negative values too.
Parameter 20: Switch type
This parameter defines as what type the device should treat the switch connected to the S1 and
S2 terminals.
This parameter is not relevant in gate operating modes (parameter 151 set to 3 or 4). In this case
switch always works as a momentary and has to be connected to S1 terminal.
Size: 1 Byte, Default Value: 2
Setting
Description
0
momentary switches
1
toggle switches
2
single, momentary switch (the switch should be connected to S1 terminal)
Parameter 24: Inputs orientation
This parameter allows reversing the operation of switches connected to S1 and S2 without
changing the wiring.
Size: 1 Byte, Default Value: 0
Setting
Description
0
default (S1 – 1st channel, S2 – 2nd channel)
1
reversed (S1 – 2nd channel, S2 – 1st channel)
Parameter 25: Outputs orientation

Other manuals for FIBARO ROLLER SHUTTER 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO ROLLER SHUTTER 3 and is the answer not in the manual?

FIBARO ROLLER SHUTTER 3 Specifications

General IconGeneral
Device TypeRoller Shutter Controller
ProtocolZ-Wave
Radio ProtocolZ-Wave
Dimensions42.5 x 38.25 x 20.3 mm
Mounting Box RequirementsØ ≥ 50mm, depth ≥ 60mm
Protection ClassIP20
Maximum Load for AC Output4.2A
Max Transmit Powerup to 6 dBm
RangeUp to 50m (open space)
Operating Temperature0°C to 40°C
Z-Wave Frequency868.4 MHz EU
CompatibilityWorks with various Z-Wave and Z-Wave Plus certified devices
Radio Frequency868.4 or 908.4 or 921.4 MHz EU frequency band