For a setting of this parameter, please refer to the manufacturer‘ s manual.
Size: 4 Byte, Default Value:
Parameter 35: Alarm configuration - 5th slot (Heat)
This parameter determines to which alarm frames and how the device should react. The
parameters consist of 4 bytes, three most significant bytes are set according to the official Z-
Wave protocol specification.
Size: 4 Byte, Default Value:
Parameter 40: S1 switch - scenes sent
This parameter determines which actions result in sending scene IDs assigned to them.
Size: 1 Byte, Default Value: 0
Key hold down and key released
Parameter 42: S2 switch - scenes sent
This parameter determines which actions result in sending scene IDs assigned to them.
Size: 1 Byte, Default Value: 0
Key hold down and key released
Parameter 60: Measuring power consumed by the device itself
This parameter determines whether the power metering should include the amount of active
power consumed by the device itself.
Size: 1 Byte, Default Value: 0