Running Test
Inspection Before Running Test
1. Check electrical connectors, terminal screws. Be sure all are tight
2. Check voltage at the power supply, 110-125 volts range must be observed on the outlet
3. Check Bonding wire's tightness and attachment to the ground rod.
4. Check plumbing connections, make sure all glued, tight and IN from BOTTOM, OUT from
TOP
Turn on the pump………………….
………………………..Wait about 1 minute for all the air to purge from the system
Turn on the heater
Push the ON/OFF button on the heater, Making sure the SUNSHINE sign is on top……………...
……………….ALLOW ABOUT 5 MINUTES, FOR THE FAN TO START BLOWING COLD AIR AND
CONDENSATION TO START DRIPPING.
These indicate the heater is running. Another indication of the heater operating properly, is the
pressure gauge on its side will climb up.
If all is well, leave your heater running. Your heater will only be on while your pump is ON
In and out temperatures maybe very close or even the same, but this depends on many
factors, including a strong pump pushing the water too fast to register.
The primary indicators of heating are cold air and condensation.
The Pressure gauge is oil filled with an air bubble. Do not mistake it for an oil or water leak.
1. Control Function Description
➢ “ON/OFF” key:Turn ON/OFF the heat pump.
➢ “MODE” key:Press MODE key to select, while the heater is RUNNING.
AUTO mode – Triangle Sign
COOLING mode – Snowflake sign
V.23.02 FIBROPOOL USA