36Nectra
Setting delays
3.3 Setting time delays
The lock allows the user to set a delay before opening: when a code is entered, a delay
timer is counted down before the bolt releases.
The delay timer can be set from "0" to "99" minutes.
3.3.1 Master code delay
For a frequent use of the lock with a delay, we strongly recommend that you
power your lock with an external 12V DC power supply (available as an option,
please contact your retailer).
Orange light Green light
C Type in the master code +
C When the green light is displayed, open the door.
C Door opened, type in master code again +
C Type "13" +
C Type "delay duration in minutes" +
X2
X2