Troubleshooting an “Err message
1. Measured pressure was less than 10 psig.
Refrigerant cylinder may be nearly empty.
Valves may be closed.
2. Measured pressure was not within ±3psig of VSAT pressure on
the P-T chart.
Thermocouple may not have been calibrated properly.
Thermocouple may not have been attached properly to cylinder.
Thermocouple may have not been connected to ODDB jack.
Refrigerant cylinder pressure was unstable.
Refrigerant cylinder temperature was unstable.
Refrigerant selected did not match refrigerant in cylinder.