By the use of 4 Hex switches different operating modes can be selected.
The Hex-switches must always be programmed in pairs (1 and 3, 2 and 4). Within
each pair, equal values must be programmed.
1. Operating modes without additional safety control
with / without monitoring of protective doors / monitoring of the emergency off circuits (inputs equivalent)
with monitoring of protective doors (inputs antivalent) / monitoring of the emergency off circuits (inputs equivalent)
Electrical connections - Description / Wiring diagrams
6
Programming of the integrated safety functions via Hex-switches
Doku Nr. 1379 Stand 27.1.2017 /Aui
Hex-swit-
ches
2 and 4
Hex-switch-po-
sitions
slow speed
traverse in-
formation
* switching over
tolerance enhan-
cement of the
valve position
monitors
8
9
without
without
+ 0 ms
+100 ms
A
B
C
D
without
without
+ 200 ms
+ 300 ms
with
with
+ 0 ms
+100 ms
E
F
with
with
+ 200 ms
+ 300 ms
Hex-swit-
ches
1 and 3
Hex-switch-
positions
Monito-
ring of the
foot pedal
antivalent
soft-breaking
when the
foot-pedal
was released
Start in-
terlock
for the
rear
lightgrid
Monitoring of
protective
doors / Emer-
gency OFF
equivalent swit-
ching
8
9
with
with
with
without
without
without
without
without
without
with
A
B
C
D
with
with
with
without
with
with
without
without
without
without
with
with
without
with
without
without
without
with
without
with
E
F
with
with
without
without
without
with
with
with
without
with
Hex-swit-
ches
2 and 4
Hex-switch-po-
sitions
EDM
stop val-
ves moni-
toring
slow
speed tra-
verse in-
formation
* switching over
tolerance en-
hancement of
the valve posi-
tion monitors
0
1
without
without
without
without
+ 0 ms
+100 ms
2
3
4
5
without
without
without
without
without
without
with
with
+ 200 ms
+ 300 ms
+ 0 ms
+100 ms
6
7
8
9
without
without
with
with
with
with
without
without
A
B
C
D
with
with
without
without
with
with
with
with
+ 200 ms
+ 300 ms
+ 0 ms
+100 ms
+ 200 ms
+ 300 ms
+ 0 ms
+100 ms
E
F
with
with
with
with
+ 200 ms
+ 300 ms
12 3 4
* Attention!
Select always the shortest possible switching over tolerance enhancement of the valve position monitors!
Hexswitches
Hex-swit-
ches
1 and 3
Hex-switch-po-
sitions
Monitoring
of the foot
peda
l
antivalent
soft-breaking
when the foot-
pedal was relea-
sed
EDM
stop val-
ves moni-
toring
Monitoring of the
protective doors an-
tivalent switching Mo-
nitoring of the Er-
nergency OFF
0
1
with
with
with
with
without
without
without
with
with
with
2
3
4
5
with
with
with
with
with
with
without
without
with
with
without
with
without
without
without
with
with
with
with
with
6
7
with
with
without
without
with
with
without
with
with
with
Start / Stop closing moving
Start / Stop closing moving
FIESSLER