EasyManua.ls Logo

Fiessler AKAS-3PM - Safety Functions and Monitoring

Fiessler AKAS-3PM
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KS KE KN
EDMS SGO SP EDMO SGS NLW NA1 NA3NA2 FUS FUO KAST
NC
OSSD1 OSSD2
KX KY
NC
VCC
RXOK1
RXOK2
KRX1 KRX2
M
KNCE KNCE
KY
KX
RXD
Umschalt-
punkt IN
Ab IN
Eilgangan-
forderung IN
NC
Eil OUT Ab OUT
Sicherheitspunkt
TXD
HUSP SGA +24V
KNCE KNCA
SP
KE
KS KN KNCE
KE
KS
KX
KY
KNCA
wenn KN nicht
vorhanden ist
KN
Sicherheits-
ventil
Eilgang-
ventil
Nachsaug-
ventil
Sicherheits-
ventil
Eilgang-
ventil
Nachsaug-
ventil
KRX1
KRX2
Hinteranschläge
Antrieb
Presse
schließen
KNCA KNCA
rückseitiger Resettaster für
das hintere Schutzgitter
Nachlauf-
nockenschalter
hinteres
Schutzgitter
rechtes
seitliches
Schutzgitter
linkes
seitliches
Schutzgitter
Notaus 1
Notaus 2
Eingänge AKAS
Ausgänge AKAS
kann durch die NC oder mit einem Kontakt der
Eilgang/Schleichgangumschaltung erfolgen
3-Positions-
Fußpedal
Resettaster für
Notaus und
seitliche
Schutzgitter
Kastenbiege-
anwahltaster
Schließer von
Fußpedal
Eil-/Schleichgang
+24V
+24V
Schlüsselschalter
für Justage
nur bei
AKAS®-LCF
+Ub Sender
Electrical connections - Description / Wiring diagrams
6
-with selectable safety functions
6.4
Doku Nr. 1379 Stand 27.1.2017 /Aui
Wiring example with a suitable hydraulics. AKAS is responsible for all safety related monitoring tasks
(at a Hex switch B8 B8 or F8 F8)
AKAS monitors both positions of the fast speed and slow speed state and requires:
in fast speed: at SGO = + 24 V and at SGS = 0 V
in slow speed: at SGO = 0 V and at SGS = + 24 V
During the switching over from one state into the other state, an enhancable switch-over time is tolerated.
see selectable switch-over delay enhancement of the valve position monitor
Machine-Safety monitoring by AKAS®-3PF
wiring diagram 2/ p. 30
Sicher-
heitsventil
Eilgang-
ventil / KE
Nach-
saugventil
Stop
Eil / Ab
0
1
0
1
0
0
Schleich / Ab
Auf
1
0
0
0
1
0
higher switch-
over point
request IN
(only AKAS® 3)
fast speed
request IN
safety point
box bending
selector
switch
3-positions
foot pedal
fast out
down out
rear stopper
motor
fast speed
valve / KE
safety con-
tactor / KS
rear
protective grid
right lateral
protective
grid
left lateral
protective
grid
Emergency
OFF 1
Emergency
OFF 2
overrun tra-
verse cam
switch
KNCA if KN
is not pre-
sent
rear reset button for the
rear protective grid
fast / down
slow/ down
up
Press brake
safety
valve
fast speed
valve
feeder con-
tactor / KN
prefill
valve
fast / slow speed
AKAS inputs
AKAS outputs
can be carried out by the NC or by a contact
of the slow speed/fast speed swiching over
fast speed
valve
feedback
prefill valve
feedback
safety
valve
feedback
close the
press
reset button
for emer-
gency OFF
and lateral
metal grids
+ Ub transmitter
key switch for
ajustment
only for
AKAS®-LCF
AKAS®-3PF
Picture is only showing half
of a two zylinder hydraulic
FIESSLER
E L E K T R O N I K
normally
open con-
tact of the
foot pedal