RD SERIES PORTABLE FUEL TRANSFER PUMPS
RD8, RD12
Installation and Operation Manual

Questions and Answers

  • K
    Kathleen ShawAug 5, 2025
    Why FILL-RITE RD Water Pump will not prime?
    • A
      anthony39Aug 5, 2025
      Your FILL-RITE Water Pump may not prime due to several reasons: * A suction line problem: Check for leaks or restrictions; the line may be too small, too long, not airtight, or too low vertically. * Sticking vanes: Inspect for nicks, damage, obstructions, or wear and replace if needed. * Excessive wear: Look for wear on the rotor, vanes, rotor cover, or housing; replace worn parts. * Blockage: Check the pump, hose, nozzle, and filter/strainer for any blockages. * Vapor lock: Reduce the vertical and horizontal distance from the pump to the liquid. * Reversed power connections: Ensure that the power connections are correct.
  • K
    kathleen75Aug 10, 2025
    What to do if my FILL-RITE Water Pump has low capacity?
    • N
      Nathan MckinneyAug 10, 2025
      If your FILL-RITE Water Pump has low capacity, consider the following: * Check for excessive dirt in the screen and clean it. * Inspect the suction line for leaks or restrictions; it may be too small, too long, not airtight, or too low vertically. * Examine the rotor, vanes, rotor cover, and housing for excessive wear; replace if necessary. * Replace a damaged hose or nozzle. * Refill the tank if the fluid level is low. * Check the incoming line voltage while the pump is running to ensure it's correct. * Look for sticking vanes and check for nicks, damage, obstructions, or excess wear. Replace as needed. * Check for loose wiring connections.
  • D
    Dean DelgadoAug 15, 2025
    What to do if FILL-RITE Water Pump motor stalls or fuse blows?
    • L
      Lauren StevensonAug 15, 2025
      If your FILL-RITE Water Pump motor stalls or the fuse blows, it could be due to: * A short in the wiring: Inspect the electrical cable for shorts and replace if necessary. * Excess rotor or vane wear: Check the vanes for nicks, damage, obstructions, or excess wear and replace if needed. * Pump rotor lock-up: Clean and inspect the rotor and vanes. * Debris in the pump cavity: Clean the debris from the pump cavity. * Components swell from pumping water: Let the pump dry completely.
  • B
    brownjohnAug 20, 2025
    What causes a FILL-RITE RD motor to be inoperative?
    • S
      Samuel ObrienAug 20, 2025
      A FILL-RITE Water Pump motor may be inoperative due to: * No power: Check incoming power. * Motor overheated: Switch off and allow to cool. * Incorrect or loose wiring: Check wiring / connections. * Fuse has blown: Replace the 30A fuse.
  • S
    sharon49Aug 26, 2025
    Why FILL-RITE Water Pump motor overheats?
    • N
      Nathan WrightAug 26, 2025
      The FILL-RITE Water Pump motor may overheat due to: * Pumping high viscosity fluids for extended periods (longer than the 30 min duty cycle). * A clogged screen: Remove and clean the screen. * A restricted suction pipe: Remove and clean the pipe. * Pump rotor lock-up: Clean and inspect rotor and vanes. * No power: Check incoming power. * Incorrect or loose wiring: Check wiring / connections.
  • M
    Mary FoxAug 30, 2025
    How to fix fluid leakage in FILL-RITE RD Water Pump?
    • O
      Omar PittmanAug 30, 2025
      To address fluid leakage in your FILL-RITE Water Pump: * Check all o-rings. * Tighten fasteners. * Reseal plumbing connections.

Summary

Product Safety and Definitions

Symbols and Definitions

Explains hazard symbols and their meanings for user safety.

Safety Information

Crucial safety warnings and precautions for proper operation.

Installation and Configuration

Bung Mount Configuration

How to mount the pump using a bung adapter and suction tube.

Mounting Foot and Nozzle Boot Installation

Steps for attaching the mounting foot and nozzle boot.

Suction Hose Configuration

Guidelines for selecting and connecting suction hoses for flammable fluids.

Fueling Safety

Essential safety measures to prevent explosions during fueling.

Flange Configuration

How to reconfigure inlet/outlet flanges to desired positions.

DC Power Connection

Detailed instructions for connecting the pump to a DC power source.

Operation and Maintenance

Power Switch Operation

How to use the sliding ON/OFF power switch.

Operational Safety

Precautions for safe pump operation and handling.

Cleaning the Inlet Screen

Procedure for inspecting and cleaning the pump's inlet screen.

Troubleshooting and Parts

Troubleshooting Guide

Diagnostic assistance for common pump issues and solutions.

Accessories

Lists available accessories for the RD Series pumps.

Kits and Parts

Identifies various kits and individual parts available for the pumps.

Technical Specifications and Certifications

Motor Tag Information

Details on finding technical and certification info on the pump handle.

Technical Information

Comprehensive technical data for RD8 and RD12 models.

Safety Testing Certifications

Lists safety standards and certifications applicable to the pumps.

FILL-RITE RD Series Specifications

General IconGeneral
BrandFILL-RITE
ModelRD Series
CategoryWater Pump
LanguageEnglish

Related product manuals