38
CAUSE SOLUTION
Light
The light is reaching the end of its service life or is not/no longer watertight. Replace the light using a niche (feed-through) system.
PROBLEM: The light is blinking.
TROUBLE SHOOTING
16
LIGHTING
CAUSE SOLUTION
Electrolyser circuit breaker in
the filtration electrical enclosure
•Check whether the circuit breaker has been tripped and is still open
•If the circuit breaker has not stayed open, it is not working and will have to be replaced
Electrolyser unit
If the circuit breaker is working properly but the unit does not switch on, the electrolyser unit is out of order and will have to be replaced.
CAUSE SOLUTION
Electrolyser circuit breaker in
the filtration electrical enclosure
•Check whether the circuit breaker has been tripped and is still open
•If the circuit breaker has not stayed open, it is not working and will have to be replaced
Nano PH pump
If the circuit breaker is working properly but the unit does not switch on, the electrolyser unit is out of order and will have to be replaced.
CAUSE SOLUTION
Electrolyser unit
•Set the treatment system to maximum operating capacity (10 for 100%) for 5 minutes
•Take a voltage reading from the electrolysis cell terminals
•If the voltage reading is between 0V and 2V, there is a problem with the electronics in the electrolyser unit (power board, etc)
Electrolysis cell
•Set the treatment system to maximum operating capacity (10 for 100%) for 5 minutes.
•Take a voltage reading from the electrolysis cell terminals.
•If the voltage reading is higher than 10V, the electrolysis cell is nearing the end of its service life (max. 15 days) or is not working
(above 12V), and will have to be replaced.
Cartridges
Excessively dirty cartridges will quickly consume the chlorine that is generated to clean the pool, resulting in an incorrect chlorine
production reading.
PH Level
The PH level should be between 7.0 and 7.2 to keep the chlorine at peak effectiveness
CAUSE SOLUTION
Container The pH regulator container may be empty and need replacing.
Suction strainer
Check that the suction strainer (plunger in the container) is properly inserted in the container. Often, the container only needs to be
displaced slightly for the plunger to no longer be inserted properly and stop the reducer being injected.
Hose
•The hose from the dosing pump to the container may have drawn in something that is preventing the pH reducer from reaching the pool.
•The hose may also have a hole, possibly caused by the acidity level of the reducer. If so, it will have to be replaced.
•We recommend that you replace the hose at least every two years as the acidity level of the pH reducer will gradually cause it to
become porous.
PROBLEM: The electrolyser unit does not switch on..
PROBLEM: The Nano pH pump does not switch on.
PROBLEM: The electrolyser is producing little or no chlorine.
PROBLEM: The dosing pump is not injecting pH reducer.