36
CAUSE SOLUTION
Cartridges
• SITUATION 1: The cartridges are dirty but not clogged. Clean the cartridges at more regular intervals (once every fortnight)
•SITUATION 2: Renew the cartridges if they are clogged
•SITUATION 3: If you are using a flocculent or anti-algae treatment, lower the water level by 20 cm and renew the cartridges
Leaf baskets
Clean the debris from the baskets at regular intervals and clean or renew the Netskims (skimmer socks/nets)
Pump
Clean the pump housing to remove any foreign matter and unblock the turbine
Water level
Check the water height, making sure it is ¾ of the way up to the skimmer niches
Priming
•Check that the pump has been primed properly
•If it hasn’t, remove the delivery system at the pump outlet, fill the pump with water and jolt-start the unit again on and off in
quick spurts (5 seconds on, 1 to 2 seconds off); 3 or 4 times should be enough
Position of the unit
•The 4 contact points on the rear of the side that is submerged in the pool should be hard against the pool wall
•This is only possible if you ensure that the tank section is perfectly horizontal and supported sufficiently high up to avoid strain that
would pull the contact points away from the pool (see the installation guide)
CAUSE SOLUTION
Power supply
•Check the wiring from the pump to the unit’s electrical enclosure
•Check the wiring from the electrical enclosure to the mains power supply
•Check the 30 mA circuit breaker at the line end
Pump switch
•Check the wiring to the pump switch
•eplace the switch if it is not working
Front-mounted 3-position
switch (Auto/0/Manual) on
the electrical enclosure
•Put the switch in Manual mode
•If the pump still does not work, check the connections at the wire terminals behind the switch inside the enclosure
•If the problem is still not resolved, contact your retailer to have the switch replaced
Timer
•Check the timer wiring inside the electrical enclosure
•Check that the 3-position switch (Auto/0/Manual) is turned to Auto mode
•Also turn the switch in the bottom left corner of the timer dial face to Auto
•Use the timer segments to set the filtration to start and stop at different periods
•If the filtration does not start, the timer is faulty and will have to be replaced
CAUSE SOLUTION
Turbine
Use a large flat-blade screwdriver at the rear and in the centre of the pump to try and release the turbine and get it turning
Condenser
Replace the condenser
PROBLEM : Low pressure flow and/or air bubbles in the pumped water flow
PROBLEM : The pump does not start
• If there is no noise:
• If the power unit is making a noise:
TROUBLE SHOOTING
16
FILTERS/PUMPS/CCS