Installaon and Service Informaon
Fimco High-Flo Gold Series pumps are designed to pump water and aqueous solutions of common pesticides. They are not
designed to pump petroleum products or other flammable materials. They are not designed to pump bleach solutions. Use of this
pump for petroleum products or bleach solutions will void the warranty. When pumping liquids other than water, the pump
should be flushed out with clean water after each use to prolong pump life.
High-Flo Gold Series pumps are equipped with a demand switch that reacts to outlet pressure and shuts the pump motor off at a
factory set pressure limit of 45 PSI. When the pressure drops below this preset limit the switch allows the pump motor to start again.
High-Flo Gold Series pumps are self-priming. Vertical prime will depend on the viscosity of the liquid and suction line size. Minimum
recommended suction line size is 3/8 inch. All hose connections need to be tight or air leakage will break the prime and disrupt water
flow. The installation of a 50 mesh strainer is recommended to prevent debris or other foreign material from entering the pump and
causing pump failure. The pump should be mounted in a dry and adequately ventilated area. The pump can be mounted horizontally
or vertically. If mounted vertically, the pump head should be down and the motor should be up. Your pump will come with adapters
which will allow you to hook up to various plumbing configurations. These fittings push into the ports of the pump and a slide mecha-
nism ‘locks’ them into place. Use flexible hose or tubing to connect to the inlet and outlet ports on the pump. This minimizes stress on
the pump head. Never use rigid pipe connections. Do not compress the feet. Overtightening will reduce the
ability to isolate vibration & noise.
Your pump is rated at 3.8 GPM @ open flow. If the discharge
plumbing is very restrictive or nozzle tips are undersized, the
back pressure will cause the pump to cycle rapidly. This rapid
cycling will increase the operating temperature of the motor
and the amperage draw on the power supply. Extended use
with this cycling will cause premature failure of the pump.
Your pump is designed to run off of the battery of your ATV,
lawn tractor, or other vehicle with a 12V system. If using a
stand alone battery, use a deep cycle RV or marine battery.
The pump should be winterized before storage, by pumping a
solution of RV antifreeze through it, and the entire plumbing
system.
Warranty:
Your Fimco High-Flo Gold Series pump is warranted for
one year from date of purchase for homeowner use & 90
days for commercial use, against manufacturer or work-
manship defects. Warranty claims will be processed by
Fimco Industries after the item is returned, freight prepaid,
to the Fimco Industries facility.
Pump must be flushed of all chemicals prior to returning to
Fimco. Fimco Industries assumes no liabilities for any
unwarranted equipment. Any unauthorized modifications/
alterations of the returned product will void your warranty.
All items must be returned within 30 days of failure. Ex-
penses, inconveniences, loss of chemicals, or other dam-
ages that occur, are not subject to warranty consideration.
Question and Answer IconNeed help?

Do you have a question about the Fimco High-Flo Gold Series and is the answer not in the manual?

Fimco High-Flo Gold Series Specifications

General IconGeneral
TypeCentrifugal
Housing MaterialCast Iron
Pump TypeSelf-Priming
Voltage115/230V
Weight30 lbs

Summary

Installation and Service Information

Pump Operation and Features

Explains demand switch, self-priming, mounting options, and fitting usage.

Safety Warnings

Highlights risks of injury and cancer/reproductive harm associated with product use.

Warranty Information

Details the warranty coverage, claim process, and conditions for Fimco High-Flo Gold Series pumps.

Recommended Usage Practices

Pump Maintenance and Winterization

Advises on post-use cleaning, winterization, and proper storage for pump longevity.

Prohibited Liquids and Usage

Prohibits pumping bleach, petroleum products, and using dirty water for spraying.

Pump Specifications and Troubleshooting

Pump Performance Data

Lists key performance metrics like current draw, flow rate, and liquid temperature limits.

Pressure Switch Operation Caution

Warns about improper pressure switch adjustment leading to overload or premature failure.

Troubleshooting Common Issues

Guides on diagnosing and resolving motor, priming, flow, and continuous run problems.

Detailed Troubleshooting and Maintenance

Pressure Switch Diagnosis Procedure

Outlines the procedure to test the pressure switch functionality by bypassing it.

Safety Warning for Pressure Switch Bypass

Warns about the risks associated with bypassing the pressure switch, like hose bursts.

Check Valve Cleaning Steps

Details the process of removing, cleaning, and reassembling the check valve for pressure issues.

Comprehensive Troubleshooting Guide

Lists checks for motor, pressure, flow, surging, continuous run, and fuse issues.

Limited Warranty Details

Warranty Coverage and Duration

Defines who may use the warranty and the coverage period for homeowner and commercial use.

Exclusions from Limited Warranty

Lists items and conditions not covered by the warranty, such as misuse or alterations.

Warranty Service and Remedies

Explains how to obtain service and the available remedies for defective equipment.

Limitation of Liabilities

Details limitations on implied warranties and liability for consequential damages.

Related product manuals