12 Volt, 2.2 GPM, 100 PSI
Diaphragm Pump
Model: HFP-2.2
(5281325/5151075)
Installaon and Service Informaon
Fimco High-Flo Pro Series pumps are designed to pump water and diluted chemicals for liquid applicaon with increased durability
over standard pumps. They are not designed to pump ammable materials. They are not designed to pump bleach soluons. Use
of this pump for bleach soluons will void the warranty. When pumping liquids other than water, the pump should be ushed
out with a cleaning soluon, such as Fimco Tank Neutralizer & Cleaner, or clean water mixed with a good grade dish soap aer
each use to prolong pump life.
This High-Flo Pro Series pump is equipped with a demand switch that reacts to outlet pressure and shuts the pump motor o at a
factory set pressure limit of 100 PSI. When pressure drops below this preset limit the switch allows the pump motor to start again.
High-Flo Pro Series pumps are self-priming. Vercal prime will depend on the viscosity of the liquid and sucon line size. Minimum
recommended sucon line size is 1/2 inch inside diameter hose. All hose connecons need to be ght or air leakage will break the
prime and disrupt water ow. The installaon of a 50 mesh strainer is recommended to prevent debris or other foreign material
from entering the pump and causing pump failure. The pump should be mounted in a dry and adequately venlated area. The
pump can be mounted horizontally or vercally. If mounted vercally, the pump head should be down and the motor should be
up. Your pump will come with adapters which will allow you to hook up to various plumbing conguraons. 1/2” MNST pipe
thread connecons will require pipe tape. Do not over ghten ngs causing extra stress, prematurely breaking the pump head.
Use exible hose or tubing to connect to the inlet and outlet ports on the pump. This minimizes stress on the pump head. Never
use rigid pipe connecons. Do not compress the feet. Overghtening will reduce the ability to isolate vibraon & noise.
Your pump is rated at 2.2 GPM @ open ow. If the discharge plumbing is very restricve or nozzle ps are undersized, the back
pressure will cause the pump to cycle rapidly. This rapid cycling will increase the operang temperature of the motor and the
amperage draw on the power supply. Extended use with this cycling will cause premature failure of the pump.
Your pump is designed to run o of the baery of your ATV, lawn tractor, or other vehicle with a 12V system. If using a stand alone
baery, use a deep cycle RV or marine baery.
The pump should be winterized before storage, by pumping a soluon of RV anfreeze through it, and the enre plumbing system.
WARNING: To reduce the risk of injury, the
user must read and understand the operators
manual before using this product.
WARNING: Cancer and Reproducve Harm.
www.P65Warnings.ca.gov
Retain a copy of receipt for your pump.
As it will be required to validate any warranty service.
High-Flo Pro Series Pumps are warranted against manufacturer or workmanship defects for One (1) year from date of purchase
for home owner usage and 90 days for commercial usage. See Page 6 for Warranty Informaon
Question and Answer IconNeed help?

Do you have a question about the Fimco HIGH-FLO PRO Series and is the answer not in the manual?

Fimco HIGH-FLO PRO Series Specifications

General IconGeneral
BrandFimco
ModelHIGH-FLO PRO Series
CategoryWater Pump
LanguageEnglish

Summary

Installation and Service Information

Retain Proof of Purchase for Warranty

Keep your pump receipt to validate any warranty service.

Pump Warranty Details

Details the warranty period for homeowner and commercial use.

General Safety Warnings

Essential safety precautions for pump operation and health.

Safe Operation and Handling

Battery Connection and Disconnection

Guidance on safely connecting and disconnecting the pump to a 12V battery.

Pre-Spraying Preparations

Steps for preparing the pump and sprayer before use.

Maintenance and Troubleshooting

Maintenance During/After Spraying

Instructions for cleaning the pump and sprayer after use.

Winter Storage Instructions

Steps for preparing the sprayer for winter storage.

Sprayer and Pump FAQs

Answers to common questions about pump operation and issues.

Pump Components and Troubleshooting

Available Replacement Parts

List of part numbers for pump replacement components.

Pump Troubleshooting Guide

Common issues and steps to diagnose pump problems.

Service and Repair Procedures

Checking the Switch Assembly

Procedure for testing the pressure switch functionality.

Cleaning the Valve Kit

Steps to clean the valve kit for pressure issues.

Retrofit Kit for Sprayers

Information on connecting the pump to Fimco sprayers.

Limited Warranty Information

What This Limited Warranty Covers

Details coverage and duration for new Fimco equipment.

What Is Not Covered

Exclusions from the limited warranty coverage.

Obtaining Warranty Service

Procedure for contacting Fimco for warranty claims.

Remedies and Limitations

Details available remedies and warranty limitations.

Related product manuals