EasyManua.ls Logo

Fimco HIGH-FLO HFP-24000-214 User Manual

Fimco HIGH-FLO HFP-24000-214
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
OWNERS MANUAL
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5194687 (01/22)]
12 Volt, 2.4 GPM, 60 PSI
Bypass Diaphragm Pump
Model: HFP-24000-214
(5281373/5151089)
Installaon and Service Informaon
Fimco High-Flo High Performance pumps are designed to pump water and aqueous soluons of common pescides. They are not
designed to pump petroleum products or other ammable materials. They are not designed to pump bleach soluons. Use of this
pump for petroleum products or bleach soluons will void the warranty. When pumping liquids other than water, the pump
should be ushed out with a cleaning soluon, such as Fimco Tank Neutralizer & Cleaner, or clean water mixed with a good grade
dish soap aer each use to prolong pump life.
This High-Flo High Performance pump is equipped with an internal bypass valve with a factory set pressure limit. When the system
pressure hits the limit, the internal valve will open and circulate uid internally to relieve excess pressure. Operang the pump for
longer than 10 minutes in the bypass stage, discharge is closed, could damage the check valve. The motor will connue to run unl
the pump is shut o with the manual switch located in the lead wire or the pump is disconnected from the power source.
High-Flo High Performance pumps are self-priming. Vercal prime will depend on the viscosity of the liquid and sucon line size.
Minimum recommended sucon line size is 3/8 inch. Make sure all hose clamps are ght before tesng or spraying for the rst
me. The installaon of a 50 mesh strainer is recommended to prevent debris or other foreign material from entering the pump
and causing pump failure. The pump should be mounted in a dry and adequately venlated area. The pump can be mounted hori-
zontally or vercally. If mounted vercally, the pump head should be down and the motor should be up. This pump has 3/8” fe-
male pipe threads at the inlet and outlet ports. Use 3/8” male pipe threaded ng to connect to this pump. Use exible hose or
tubing to connect to the inlet and outlet ports on the pump. This minimizes stress on the pump head. Never use rigid pipe connec-
ons. Do not compress the feet. Overghtening will reduce the ability to isolate vibraon & noise.
Pump is rated at 2.4 GPM @ open ow.
Pump is designed to run o of the baery of your ATV, lawn tractor, or other vehicle with a 12V system. If using a stand alone
baery, use a deep cycle RV or marine baery.
The pump should be winterized before storage, by pumping a soluon of RV anfreeze through it, and the enre plumbing system.
Retain a copy of receipt for your pump.
As it will be required to validate any warranty service.
High-Flo High Performance Pumps are warranted against manufacturer or workmanship defects forTwo (2) years from date of
purchase for home owner usage and 90 days for commercial usage.
See Page 6 for Warranty Informaon
WARNING: To reduce the risk of injury, the
user must read and understand the operators
manual before using this product.
WARNING: Cancer and Reproducve Harm.
www.P65Warnings.ca.gov
Question and Answer IconNeed help?

Do you have a question about the Fimco HIGH-FLO HFP-24000-214 and is the answer not in the manual?

Fimco HIGH-FLO HFP-24000-214 Specifications

General IconGeneral
BrandFimco
ModelHIGH-FLO HFP-24000-214
CategoryWater Pump
LanguageEnglish

Related product manuals