Do you have a question about the Fimco HIGH-FLO HFP-24000-214 and is the answer not in the manual?
Details the pump's electrical, flow, pressure, and model specifications.
Provides guidance on proper pump mounting, hose connections, and strainer installation.
Outlines essential flushing procedures, bypass operation, and winterization for pump longevity.
Emphasizes testing the system with water before chemical use to identify leaks.
Covers critical warnings, protective gear, battery connection, and usage restrictions.
Details recommended actions before, during, and after spraying operations.
Instructions for cleaning the pump and sprayer after use to prevent chemical damage.
Guidance on preparing the pump and system for winter storage using antifreeze.
Addresses frequent issues like pump running continuously, surging, or not starting.
Highlights essential usage prohibitions and recommended practices.
Provides solutions for problems like pump not running, no prime, blown fuses, and surging.
Step-by-step guide to cleaning the check valve to resolve low-pressure problems.
Displays pump's current draw and flow rate at various pressure levels.
Details the warranty period, what is covered, and limitations for new Fimco equipment.
This document is the owner's manual for the Fimco High-Flo High Performance Bypass Diaphragm Pump, model HFP-24000-214 (5281373/5151089).
The Fimco High-Flo High Performance pump is designed for pumping water and aqueous solutions of common pesticides. It is explicitly stated that the pump is not designed for petroleum products, other flammable materials, or bleach solutions. Using the pump for these prohibited substances will void the warranty. When pumping liquids other than water, the pump should be flushed with a cleaning solution (such as Fimco Tank Neutralizer & Cleaner) or clean water mixed with a good grade dish soap after each use to prolong its life.
This pump is equipped with an internal bypass valve with a factory-set pressure limit. When the system pressure reaches this limit, the internal valve opens, circulating fluid internally to relieve excess pressure. Operating the pump for longer than 10 minutes in the bypass stage (when discharge is closed) could damage the check valve. The motor will continue to run until it is shut off via the manual switch on the lead wire or by disconnecting it from the power source.
The pump is self-priming, with vertical prime depending on the liquid's viscosity and suction line size. It is designed to run off a 12V system, such as an ATV battery, lawn tractor battery, or other vehicle battery. For stand-alone use, a deep cycle RV or marine battery is recommended.
| Brand | Fimco |
|---|---|
| Model | HIGH-FLO HFP-24000-214 |
| Category | Water Pump |
| Language | English |