Do you have a question about the Fimco HIGH-FLO HFP-24060-113 and is the answer not in the manual?
Details the demand switch operation, self-priming capability, and performance limits for the High-Flo pump.
Provides guidance on pump mounting location, hose connections, strainer recommendations, and minimizing stress.
Covers power source recommendations for 12V systems and procedures for winterizing the pump for storage.
Instructs users to retain the pump receipt for validating warranty service and mentions defect coverage periods.
Warning to read the operator's manual before using the product to reduce the risk of injury.
Provides a warning regarding Cancer and Reproductive Harm, directing users to P65Warnings.ca.gov.
Troubleshooting steps for a pump motor that fails to start, including wiring, switch, fuse, and voltage checks.
Diagnoses for pump priming failures, covering air leaks, debris in the check valve, and supply issues.
Identifies causes for low pressure or flow, such as discharge line restrictions, nozzle clogs, or low voltage.
Addresses causes of pulsating flow, including low flow, spray pattern adjustment, and pressure switch issues.
Troubleshooting steps for a pump that runs without shutting off, checking bypass valves and system leaks.
Lists potential reasons for a fuse blowing, such as excessive voltage, pressure switch adjustment, or wiring faults.
Step-by-step guide to test the pressure switch functionality by bypassing it, with warnings.
Instructions for cleaning the pump's check valve to restore pressure and priming, including disassembly.
Defines the warranty applicability to the original purchaser and not subsequent owners.
Specifies the warranty duration for homeowner (2 years) and commercial (90 days) use.
Lists conditions and circumstances not covered by the limited warranty, such as misuse or alteration.
Outlines the procedure for obtaining warranty service, including written notice and making equipment available.
Details Fimco's liability and remedies, primarily repair or replacement of defective parts or equipment.
States limitations on implied warranties and Fimco's liability for consequential, incidental, or punitive damages.
| Brand | Fimco |
|---|---|
| Model | HIGH-FLO HFP-24060-113 |
| Category | Water Pump |
| Language | English |
Loading...