Firebird Enviromax Condensing Range
6
44
6.2 - POSITIONING THE BOILER
Ensure that adequate clearance is available for making the water and flue connections.
As the boiler is serviced from the front,no headroom clearance is necessary but a
clearance of 750mm must be available at the front of the boiler.
No special hearth is required as the boiler is fully insulated,but the floor must be
level and capable of supporting the weight of the boiler and its water content.
Sound levels must also be a consideration.Whilst Firebird Enviromax boilers are one of the quietest boilers on
the market,some householders are particularly sensitive and the following points should be considered:
1. Tiled surfaces in a small room will amplify noise - particularly if the wall construction is hollow.
2. If a conventional flue passes through a bedroom it is capable of transmitting noise.
3. Low level balanced flue terminals can produce exhaust noise on the outside terminal
and this should be considered when siting near adjacent property.
4. The Firebird Balanced Flue Kit has been specifically designed for
Firebird’s indoor boilers.The use of third party low level flue kits
is not recommended and will affect its warranty.
5. The Siting of the boiler should take into account
the disposal of condensate products.
It is recommended that a suitable
corrosion inhibitor is added to the
heating system.
New and existing systems should be
treated with chemical cleaner and
properly flushed before the boiler is
fitted and corrosion inhibitor added.
In areas of hard water a suitable
descaler would also be required.
Allow a 25mmm clearance around
the flue from combustible surface
.
Seal with flange or silicon to
prevent ingress of moisture
and combustion gas
25mmm 25mmm
Allow a 25mmm clearance around
the boiler from combustible surface
.
Fig. 1