Firebird Enviromax Condensing Range
6
46
6.3 - CONDENSATE DISPOSAL - OPTION 2
CONDENSATE DISPOSAL
SYSTEM NO.2 - CONDENSATE PUMP
IMPORTANT
Firebird condensing boilers when in condensing mode extract more heat from the flue products and the resulting
condensate which is mildly acidic needs to be drained from the boiler via a condensate pipe to the drainage system.
Provision must be made for the removal of condensate from the boiler to a internal soil stack, waste pipe,
external soil stack,gully or soak-away as per BS6798.
The 75mm trap is provided with the boiler and situated on the front of the boiler (under the cleaning door) as per
figure 1,page 45.This should be checked at regular intervals and cleaned at annual service.
The condensate line should be plastic and minimum diameter of 22mm.
Copper or steel cannot be used.
A fall from the boiler of 1:40 minimum.
As few bends as possible to reduce the risk of trapping condensate.
CONDENSATE PIPEWORK THAT IS EXTERNAL OR IN AN UNHEATED GARAGE SHOULD NOT
EXCEED 3 METERS AND LAGGED WITH WATER PROOF INSULATION TO PREVENT FREEZING.
CONDENSE PUMP (KIT IS AVAILABLE AS AN OPTIONAL EXTRA)
PART NUMBERS
Condense Pump 111508
Hose tail connection 111510
Hose pipe 111509
Stack
Ground Level
To Condense Pump.
Condense Drain
From
Condense
Pump to
Drain.
Boiler
10 mm Griflex Tubing
Discharge Pipe
Condense Pump Performance
Flow rate: 7.2 l/min
Lift: 5.m
Head: 8.m
Condense
Pump wired
in to come
on with burner.
Condense
Pump.
Hose pipe.
Out to drain.
Inlet connected
to condense drain
at base of boiler
must be into
a sealed pipe
Out
Inlet
Hose tail connection.
Kitchen Control Panel.
Brown
L2
L1
N
Inlet connected to condense drain at base of boiler
Out to drain.
Out to drain.
Condense
Pump.
Inlet
Combi
Control Panel.
MIN. = 60˚C.
MAX. = 80˚C.
MIN.
MAX.
MID.
Stack
Ground Level