EasyManuals Logo

FireBird Enviromax Popular C20 User Manual

FireBird Enviromax Popular C20
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Firebird Enviromax Condensing Range
6
49
6.4 - FLUES REGULATIONS
BALANCED FLUE BOILERS
The Firebird boiler may be set for Room-sealed balanced flue operation using a Firebird condensing
balanced flue kit. This kit does not draw combustion air from inside the room. It is drawn from
outside direct to burner by airpipe supplied with boiler. Flue gases are expelled through the same
kit. However, if the boiler is installed in a compartment or small room, some ventilation air is
necessary to maintain acceptable temperature in boiler area.
Use of any equipment other then the matching Firebird low level roomsealed
concentric flue kit is not guaranteed for low level discharge and will probably
invalidate the warranty.
Balanced flue boiler in room (eg.kitchen) does not require individual ventilation.
BALANCED - FLUE BOILERS IN COMPARTMENTS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FireBird Enviromax Popular C20 and is the answer not in the manual?

FireBird Enviromax Popular C20 Specifications

General IconGeneral
BrandFireBird
ModelEnviromax Popular C20
CategoryBoiler
LanguageEnglish

Related product manuals